background image

PRO-PAK 

8

 

5. 

Remove  the  cylinder  by  sliding  it 

through  the  loosened  cylinder  band  in 

either direction, as desired. 

CAUTION: 
Before  installing  a  cylinder  onto  the 

backplate,  ensure  that  the  protective 

edge strip is in position on the buckle 

pivot bracket.

 

6. 

Slide a fully-charged cylinder along 

the  backplate  and  through  the  loosened 

cylinder band. Position the cylinder valve 

outlet through the cylinder valve retainer. 

 

7. 

Apply gentle pressure to the clamp 

mechanism  by  pushing  downwards  and 

toward  the  cylinder  to  close  the 

mechanism  and  tighten  the  cylinder 

band.  The  clamp  mechanism  will  lock 

automatically when closed. 

 

8. 

Check  that  the  cylinder  handwheel 

connector  O-ring  is  clean  and  in  good 

condition.  Screw  the  cylinder  connector 

firmly into the cylinder valve outlet. 

Should it become necessary to adjust the 

size of the cylinder band: 
i) 

Ensure  that  the  clamp  mechanism 

is unlocked and in the open position. 
ii)

 

Adjust  the  tension  of  the  cylinder 

band using the slide buckle. 
iii)

 

Close  the  clamp  mechanism  and 

check  that  the  cylinder  is  held  securely. 

Repeat as necessary. 

3.3  REPLACING DUO 

CYLINDERS

 

1. 

Close both cylinder valves. 

2. 

Open the facemask bypass to vent 

the system. 
3. 

Undo both cylinder connectors. 

 

4. 

Use the thumb of your right hand to 

push  the  release  tag  away  from  the 

clamp  mechanism  in  the  direction  of  the 

arrow that appears on the moulded clamp 

cover.  The  clamp  mechanism  will  open, 

allowing the cylinder nearest to the clamp 

to move freely within the cylinder band. 
5. 

Remove  the  freed  cylinder  by 

sliding  it  through  the  loosened  cylinder 

band in either direction, as desired. 

 

 

Содержание PRO-PAK

Страница 1: ...PRO PAK Self contained Breathing Apparatus User Instructions Article No 2014234 Issue D 12 2005...

Страница 2: ...FACEMASK 12 3 7 1 All Facemasks 12 3 7 2 Facemasks with a Web Harness 12 3 7 3 Facemasks with a Net Harness 13 3 8 POSITIVE PRESSURE TEST 13 3 9 WHISTLE TEST 14 3 10 AIRLINE AND DECONTAMINATION ATTACH...

Страница 3: ...the tasks being undertaken and the hazards likely to be encountered Please refer to National Regulations for guidance Adequate protection may not be provided in certain highly toxic atmospheres The ap...

Страница 4: ...lations Unless otherwise specified the contaminants shall not exceed the permissible exposure level National regulations must be observed The mineral oil content shall be such that the air is without...

Страница 5: ...ese instructions and national regulations These instructions cannot replace an accredited training course run by fully qualified instructors in the proper and safe use of SCOTT breathing apparatus Ple...

Страница 6: ...89 Chiswick High Road London W4 4AL United Kingdom Please call Scott Health and Safety Limited for further apparatus approval details This manual contains user instructions for single cylinder twin cy...

Страница 7: ...2 62 8 8 12 0 Note Only cylinders in the shaded areas above are suitable for use with Pro Pak Duo in the twin cylinder configuration The total apparatus weight must not exceed 18 kg when fully charged...

Страница 8: ...ith the IRIS data communications system the warning whistle and pressure gauge are incorporated within the IRIS unit The warning whistle sounds when pressure in the cylinder falls to 55 bar 5 bar The...

Страница 9: ...detailed in Section 1 2 9 FACEMASKS Pro Pak is approved for use with Vision 3 PanaSeal PanaVisor and Pro Mask PP full facemasks all of which conform to EN 136 Class 3 All are available with five poin...

Страница 10: ...e airline connector is in good condition and that it connects securely to the Pro Pak pigtail iii The air supply conforms to EN 132 see Section 1 3 Compressed Air Airline Supplies iv The Pro Pak airli...

Страница 11: ...ndition Screw the cylinder connector firmly into the cylinder valve outlet Should it become necessary to adjust the size of the cylinder band i Ensure that the clamp mechanism is unlocked and in the o...

Страница 12: ...emoval ie the last to be removed is the first to be replaced 10 Slide a fully charged cylinder along the backplate and through the loosened cylinder band Position the cylinder outlet through the cylin...

Страница 13: ...LE CYLINDER Pro Pak Duo can be adapted to accommodate either one or two cylinders Conversion is a straightforward process in which no tools are required To convert from Duo to single cylinder applicat...

Страница 14: ...al To convert from single cylinder to Duo cylinders carry out the reverse of the above sequence of operations 3 5 RESET DEMAND VALVE 1 Press the black rubber reset button on the side of the DV and che...

Страница 15: ...ervice 3 7 DV AND FACEMASK 3 7 1 All Facemasks 1 Check that the facemask is clean and undamaged 2 Check that the orange O ring on the DV outlet is clean and in good condition 3 Fit the DV to the facem...

Страница 16: ...8 POSITIVE PRESSURE TEST 1 With the cylinder valve open insert a finger under faceseal and check for a steady outward flow of air Remove finger and allow mask to re seal 2 Hold breath for ten seconds...

Страница 17: ...ment does not leak 6 DO NOT use attachments that show signs of excessive wear or damage or that leak excessively 7 Replace dust caps 3 11 RSM ATTACHMENTS 1 Remove RSM dust caps and attach a rescue mas...

Страница 18: ...on the shoulder strap ends until the apparatus fits comfortably then close the waistbelt and tighten the slide buckle Note If the waistbelt is closed first tightening the shoulder straps will pull up...

Страница 19: ...o the chin cup and pull the mask onto the face Grasp the pull strap at the rear of the net harness and pull the net over the head 2 Tighten harness side straps DO NOT over tighten 3 Inhale deeply to a...

Страница 20: ...the cylinder valve s is are fully open and that the pressure gauge shows that there is sufficient air 2 Turn on the DV bypass knob and check for a steady flow of air into the mask Close the bypass kn...

Страница 21: ...Release the handwheel locking mechanism and close the cylinder valve s 4 Open the DV bypass knob to depressurise the system then turn the bypass to OFF 5 Release the waistbelt buckle slacken shoulder...

Страница 22: ...cle Numbers 2008247 and 2008248 respectively Pump dispensers are available for the above under Article Numbers 1017672 1 litre and 1017670 5 litres TriGeneTM disinfecting wipes are available from Scot...

Страница 23: ...ations in a Breathing Apparatus Logbook available from Scott Health and Safety Limited under Article Number 1034745 Information recorded usually includes Name and address of employer responsible for t...

Страница 24: ...st be kept up to date and available for inspection Please see Section 6 3 for details 7 2 ANNUALLY Pro Pak must be returned for a workshop service annually and for a major workshop service at six year...

Страница 25: ...Scott Health and Safety Limited Pimbo Road West Pimbo Skelmersdale Lancashire WN8 9RA United Kingdom T l 44 0 1695 711711 Fax 44 0 1695 711775...

Отзывы: