6. AFTER USE
Pro-Pak
must be cleaned and tested as
detailed in the following instructions.
6.1 CLEANING
CAUTIONS:
•
DO NOT immerse the DV or
warning whistle in water.
•
USE
ONLY
the
specified
methods and materials. DO NOT
use bleach, solvent, detergent or
abrasive cleaners.
•
Dry thoroughly, away from direct
heat and sunlight, prior to
storage.
1.
Disconnect DV from the facemask.
2.
Wash and disinfect the mask
thoroughly in a solution of
TriGene
TM
and
warm water (see following note).
3.
Rinse the mask thoroughly in clean
running water. Pay particular attention to
flushing out the exhale valve.
4.
Hang mask by its neckstrap and
allow it to dry thoroughly away from direct
heat or sunlight.
5.
When dry, wipe facemask seals
with
TriGene
TM
disinfectant wipes.
6.
Polish the visor inside and out with
a clean, lint-free cloth and slacken the
head-harness, ready for use.
Note:
TriGene
TM
is available from
Scott
Health
and Safety Limited
in 1 litre and 5 litre
containers under Article Numbers
2008247 and 2008248 respectively.
Pump dispensers are available for the
above under Article Numbers 1017672 (1
litre) and 1017670 (5 litres).
TriGene
TM
disinfecting
wipes
are
available from
Scott Health and Safety
Limited
under Article Number 2004225
(pack of 20).
7.
The harness can be sponged clean
with a mild solution of soap and warm
water. Rinse thoroughly and dry in a well
ventilated room away from direct heat
and sunlight.
8.
Fully slacken cylinder band,
shoulder straps and waistbelt; and detach
the lumbar pad. Release the hose
retaining press-studs (if fitted) and
separate the pneumatics from the
harness.
9.
In extreme cases, remove the
pneumatics from the harness to gain full
access for cleaning. The lumbar pad
filling is closed-cell foam that will not
absorb water. DO NOT store until
completely dry.
CAUTION:
DO NOT immerse the DV.
10. Fit the yellow cap on the DV outlet.
11. If required, use a small brush (eg
toothbrush) and a mild solution of soap
and warm water to clean around the
locking catch and bypass knob.
12. Clean the valve body using a lint-
free cloth moistened in a mild solution of
soap and warm water. DO NOT store
apparatus until completely dry.