PRO-PAK 

4

 

 

Weight of Pro-Pak 

with Cylinder 

(kg) 

Cylinders 

Water 

Capacity 

(litres) 

Charging 

Pressure 

(bar) 

Free air 

Volume 

(litres) 

Nominal 

Duration 

(mins) 

Warning 

Period 

(mins) 

Total 

Duration 

(mins) 

Cylinder 

Charged 

Weight 

(kg) 

Single 

Duo 

CYL-1200 

6.0 

200 

1200 

22 

30 

8.8 

12.0 

CYL-HWG- 

1200  

6.0 

207 

1200 

22 

30 

7.2 

10.4 

CYL-FWC- 

1300 

4.7 

300 

1300 

25 

32 

5.0 

8.2 

CYL-1640 

6.0 

300 

1640 

33 

41 

12.5 

15.7 

CYL-HWG- 

1640 

6.0 

300 

1640 

33 

41 

10.0 

13.2 

CYL-FWC- 

1640 

6.0 

300 

1640 

33 

41 

6.3 

9.5 

16.0 

CYL-1800 

9.0 

200 

1800 

33 

12 

45 

13.0 

16.2 

CYL-HWG-

1800 

9.0 

207 

1800 

33 

12 

45 

11.2 

14.4 

CYL-FWC- 

1800 

9.0 

207 

1800 

33 

12 

45 

6.75 

9.95 

18.0 

CYL-FWC- 

1860 

6.8 

300 

1860 

37 

46 

6.75 

9.95 

18.0 

CYL-FWC- 

2460 

9.0 

300 

2460 

50 

12 

62 

8.8 

12.0 

Note:

  Only cylinders in the shaded areas (above) are suitable for use with 

Pro-Pak Duo

 in 

the twin-cylinder configuration. The total apparatus weight must not exceed 18 kg when fully-

charged; (ref: EN 137, Clause 5.4). 

Table 3:  Cylinders approved for use with Pro-Pak apparatus 

Table 4

 identifies the cylinder material code and cylinder specification. 

Code 

Material 

Specification 

No Code 

Steel  (e.g.: CYL-1200) 

CE Marked 

HWG 

Hoop Wrapped Glass Fibre  (e.g.: CYL-HWG-1200) 

HSE-AL-HW1 

FWC 

Fully Wrapped Carbon  (e.g.: CYL-FWC-1300) 

CE Marked 

Table 4:  Cylinder Codes and Specifications 

Durations are nominal and based on an Average Wearer Consumption Rate of 40 L/min and 

are for 

fully charged cylinders. 

Cylinder Free Air Capacity

 

Total Duration = 

Average Wearer Consumption Rate

 

   

 

Nominal Duration =

 

             

 

Total Duration minus the Warning Period. 

Whistle Operating Pressure

 

Warning Period = 

Average Wearer Consumption Rate

 

 

Содержание PRO-PAK

Страница 1: ...PRO PAK Self contained Breathing Apparatus User Instructions Article No 2014234 Issue D 12 2005...

Страница 2: ...FACEMASK 12 3 7 1 All Facemasks 12 3 7 2 Facemasks with a Web Harness 12 3 7 3 Facemasks with a Net Harness 13 3 8 POSITIVE PRESSURE TEST 13 3 9 WHISTLE TEST 14 3 10 AIRLINE AND DECONTAMINATION ATTACH...

Страница 3: ...the tasks being undertaken and the hazards likely to be encountered Please refer to National Regulations for guidance Adequate protection may not be provided in certain highly toxic atmospheres The ap...

Страница 4: ...lations Unless otherwise specified the contaminants shall not exceed the permissible exposure level National regulations must be observed The mineral oil content shall be such that the air is without...

Страница 5: ...ese instructions and national regulations These instructions cannot replace an accredited training course run by fully qualified instructors in the proper and safe use of SCOTT breathing apparatus Ple...

Страница 6: ...89 Chiswick High Road London W4 4AL United Kingdom Please call Scott Health and Safety Limited for further apparatus approval details This manual contains user instructions for single cylinder twin cy...

Страница 7: ...2 62 8 8 12 0 Note Only cylinders in the shaded areas above are suitable for use with Pro Pak Duo in the twin cylinder configuration The total apparatus weight must not exceed 18 kg when fully charged...

Страница 8: ...ith the IRIS data communications system the warning whistle and pressure gauge are incorporated within the IRIS unit The warning whistle sounds when pressure in the cylinder falls to 55 bar 5 bar The...

Страница 9: ...detailed in Section 1 2 9 FACEMASKS Pro Pak is approved for use with Vision 3 PanaSeal PanaVisor and Pro Mask PP full facemasks all of which conform to EN 136 Class 3 All are available with five poin...

Страница 10: ...e airline connector is in good condition and that it connects securely to the Pro Pak pigtail iii The air supply conforms to EN 132 see Section 1 3 Compressed Air Airline Supplies iv The Pro Pak airli...

Страница 11: ...ndition Screw the cylinder connector firmly into the cylinder valve outlet Should it become necessary to adjust the size of the cylinder band i Ensure that the clamp mechanism is unlocked and in the o...

Страница 12: ...emoval ie the last to be removed is the first to be replaced 10 Slide a fully charged cylinder along the backplate and through the loosened cylinder band Position the cylinder outlet through the cylin...

Страница 13: ...LE CYLINDER Pro Pak Duo can be adapted to accommodate either one or two cylinders Conversion is a straightforward process in which no tools are required To convert from Duo to single cylinder applicat...

Страница 14: ...al To convert from single cylinder to Duo cylinders carry out the reverse of the above sequence of operations 3 5 RESET DEMAND VALVE 1 Press the black rubber reset button on the side of the DV and che...

Страница 15: ...ervice 3 7 DV AND FACEMASK 3 7 1 All Facemasks 1 Check that the facemask is clean and undamaged 2 Check that the orange O ring on the DV outlet is clean and in good condition 3 Fit the DV to the facem...

Страница 16: ...8 POSITIVE PRESSURE TEST 1 With the cylinder valve open insert a finger under faceseal and check for a steady outward flow of air Remove finger and allow mask to re seal 2 Hold breath for ten seconds...

Страница 17: ...ment does not leak 6 DO NOT use attachments that show signs of excessive wear or damage or that leak excessively 7 Replace dust caps 3 11 RSM ATTACHMENTS 1 Remove RSM dust caps and attach a rescue mas...

Страница 18: ...on the shoulder strap ends until the apparatus fits comfortably then close the waistbelt and tighten the slide buckle Note If the waistbelt is closed first tightening the shoulder straps will pull up...

Страница 19: ...o the chin cup and pull the mask onto the face Grasp the pull strap at the rear of the net harness and pull the net over the head 2 Tighten harness side straps DO NOT over tighten 3 Inhale deeply to a...

Страница 20: ...the cylinder valve s is are fully open and that the pressure gauge shows that there is sufficient air 2 Turn on the DV bypass knob and check for a steady flow of air into the mask Close the bypass kn...

Страница 21: ...Release the handwheel locking mechanism and close the cylinder valve s 4 Open the DV bypass knob to depressurise the system then turn the bypass to OFF 5 Release the waistbelt buckle slacken shoulder...

Страница 22: ...cle Numbers 2008247 and 2008248 respectively Pump dispensers are available for the above under Article Numbers 1017672 1 litre and 1017670 5 litres TriGeneTM disinfecting wipes are available from Scot...

Страница 23: ...ations in a Breathing Apparatus Logbook available from Scott Health and Safety Limited under Article Number 1034745 Information recorded usually includes Name and address of employer responsible for t...

Страница 24: ...st be kept up to date and available for inspection Please see Section 6 3 for details 7 2 ANNUALLY Pro Pak must be returned for a workshop service annually and for a major workshop service at six year...

Страница 25: ...Scott Health and Safety Limited Pimbo Road West Pimbo Skelmersdale Lancashire WN8 9RA United Kingdom T l 44 0 1695 711711 Fax 44 0 1695 711775...

Отзывы: