CLEANING AND SANITIZING
MONTHLY & INITIAL START UP:
Sanitize the Ice Storage System.
Note: this should only be done by qualified
personnel.
1. Unplug the Ice Stand’s electrical cord from the
electrical power.
2. Remove cover and discard all remaining ice.
3. Mix a solution of 1 ounce of household bleach to
2 gallons of potable water, or: mix a solution of any
approved sanitizer, following the directions for
mixing and applying that sanitizer.
4. Remove the ice chute (if used) by lifting one end
and pulling out of the slots. Unscrew the sweep
arm from the rotor shaft, and pull the rotor from
hopper.
5. Using a clean cloth or sponge, wipe all interior
surfaces of the ice storage hopper with the
sanitizing solution, allow to air dry.
6. Wipe all surfaces of the rotor (plus ice chute,
shield and bearing if used) with the sanitizing
solution, and allow to air dry.
7. Lift up & out and remove the upper front panel.
A. Twist the clear ice chute 1/3 turn, and pull down
to remove.
B. Locate the two
thumb screws holding
the upper ice chute;
remove them (1 on
top and 1 below).
Remove the upper ice
chute from the
machine.
Thoroughly wipe the
surfaces of the bin
door and both ice
chutes with the
sanitizing solution, and allow to air dry.
Place the upper ice chute back onto the dispenser,
secure with the three thumb screws.
Place the clear ice chute back onto dispenser.
Place the upper front panel back onto the machine.
8. Wipe the inside surface of the cover with the
sanitizing solution, and allow to air dry.
9. Reassemble the rotor and hopper, re-wipe the
surfaces of the rotor and allow to air dry.
10. Wipe the top edge of the ice hopper with the
sanitizing solution, allow to air dry.
11. Pour in fresh, sanitary ice and replace the
cover. Plug the unit in, and it is now ready to
dispense ice.
Ice hopper contains parts
that can move at any
time, and will cause
injury if hands are in the
way.
Do
not
remove cover
until the unit has been
unplugged from the
electrical power.
SWEEP
ARM
ROTOR
CLEAR
CHUTE
UPPER ICE
CHUTE
LIFT UP &
OFF PANEL
IS160 and IS220
August 1995