background image

REMOVAL & REPLACEMENT

To Replace Vend Switch:

1. Disconnect Electrical Power.

2. Pull out and remove upper front panel.

Lever Type

A. Twist ice chute 1/3 turn and pull down to
remove.

B. Remove screws holding mounting plate to
cabinet.  Pull plate assembly out and away from
cabinet. Switch is mounted to valve plate.

Push Button 

A. Locate vend switch behind push button.

B. Remove wires from switch.

C. Remove screw & nut retaining switch to
mounting plate, and remove switch from dispenser.

3. Reverse steps to reassemble.

To Replace Gear Motor Assembly:

1. Disconnect electrical power.

2. Remove cover from hopper.

3. Unscrew sweep arm holding rotor to gearmotor
shaft.

4. Remove rotor from gearmotor shaft.

5. Remove splash panel

6. Twist ice chute 1/3 turn and pull down to remove.

7. Remove ice chute mounting plate.

8. Remove screws holding valve mounting plate to
cabinet. Pull valve assembly out and away from
cabinet.

9. Mark location of gearmotor bracket on cabinet.

10. Disconnect gearmotor electrical leads in
control box.

11. Remove (4) screws holding gearmotor to
bracket..

12. Remove (4) screws holding bracket to cabinet.

13. Pull gearmotor bracket from cabinet.

14. Dismount gearmotor from dispenser.

15. Reverse to reassemble. Gearmotor bracket
should be installed where it was, so that the rotor
should clear bin surface by 1/8" to 1/4". If needed,
the slots on the gearmotor bracket will allow the
position of the rotor to be adjusted.

To Replace Solenoid:

1. Disconnect electrical power.

2. Pull out and remove upper front panel. Remove
fluorescent tube light if used.

3. Remove 2 thumb screws holding lower brace
and remove.

4. Remove 3 thumb screws holding upper ice
chute cover, and remove cover.

5. Disconnect electrical leads from solenoid.

6. Straighten cotter pin, and remove pin from
solenoid plunger.

7. Remove rubber mounting screws holding
solenoid to cabinet, and remove solenoid from
cabinet.

8. Reverse to reassemble.

To Replace Light: (Optional)

1. Disconnect electrical power.

2. Pull out and remove upper front panel.

3. Twist fluorescent tube out of sockets.

4. Reverse to reassemble.

Electrical Shock
Hazard.

Unplug unit before
servicing.

LIGHT TUBE

IS160 and IS220

August 1995

Page 12

Содержание IS160

Страница 1: ...ler Page 4 Initial Start Up Page 6 How it Works Page 7 For the Operator Page 8 Cleaning Sanitizing Page 9 Service Diagnosis Page 11 Electrical Sequence Page 11 Repair Page 12 Parts lists and wiring di...

Страница 2: ...plug Rotor motor is 1 10 H P Note Not all ice is dispensed Options Push button actuation factory installed Scotsman Ice Systems are designed and manufactured with the highest regard for safety and per...

Страница 3: ...Tube 1 Slide out the ice chute mounting panel 2 Insert the ice lever into the slot as shown 3 Swing the lever through the slot from right to left and let it hang freely 4 Twist the fluorescent tube i...

Страница 4: ...r base Sufficient fittings are indluded with the unit to install in most cases 3 In order to comply with National Sanitation Foundation NSF requirements this unit must be either elevated above the cou...

Страница 5: ...With the unit located on the counter as desired A Tilt or lift the unit to expose the bottom flanges of the base frame B Apply the sealant to cover the bottom flanges of the base frame C Return the un...

Страница 6: ...time and will cause injury if hands are in the way Do not remove cover until the unit has been unplugged from the electrical power Note there is a timer in the control box that will activate the roto...

Страница 7: ...grill are clean 2 Remove cover and pour sanitary ice into the hopper Do NOT use bagged ice directly from a freezer The ice must be broken up in the bags first before adding to the hopper Large chunks...

Страница 8: ...er Will Not Be Dispensed HOW IT WORKS The ice is stored in a hopper At the front of the hopper there is an angled rotor when that rotor turns it scoops the ice lifts it to the top of the ice chute and...

Страница 9: ...ot water allowing plenty of hot water to run down the drain 3 Wash the grill then rinse with clean water Place back in sink 4 Clean all exterior surfaces of the unit with warm water and a sponge Rinse...

Страница 10: ...ute 1 3 turn and pull down to remove B Locate the two thumb screws holding the upper ice chute remove them 1 on top and 1 below Remove the upper ice chute from the machine Thoroughly wipe the surfaces...

Страница 11: ...to the gearmotor and the motor turns the rotor Stand By Relay A s contacts 7 1 are closed and make a circuit to the timer The timer is energized when the unit is not dispensing The timer switch will c...

Страница 12: ...rical leads in control box 11 Remove 4 screws holding gearmotor to bracket 12 Remove 4 screws holding bracket to cabinet 13 Pull gearmotor bracket from cabinet 14 Dismount gearmotor from dispenser 15...