FOR THE PLUMBER
CONFORM TO ALL APPLICABLE CODES
Water Inlet
The recommended water supply is
cold water. Use 3/8" O.D. copper
tubing, connect to the 3/8" male flare
at the back of the cabinet. Install a
hand valve near the machine to
control the water supply.
Drains
There is one 3/4" FPT drain at the
back of the cabinet, the drain line is of
the gravity type, and 1/4 inch per foot
fall is an acceptable pitch for the drain
tubing. There should be a vent at the
highest point of the drain line, and the
ideal drain receptacle would be a
trapped and vented floor drain. Use
only 3/4" rigid tubing.
Storage Bin:
A separate gravity type
drain needs to be run. Insulation of
this drain line is recommended.
FLOOR DRAIN
VENT BIN DRAIN
3/4" FPT
VENT ICE
MAKER
DRAIN,
3/4" FPT
WATER INLET
3/8" MALE
FLARE
FIELD
SUPPLIED
WATER FILTER
HAND SHUT
OFF VALVE
CONNECT TO
COLD WATER
NME1850R & FME2400R
January 1995
Page 9