FOR THE INSTALLER: Final Check List
1. Is the ice system installed
indoors in a location where the
air and water temperatures are
controlled, and where they do
not exceed the design
limitations?
2. Is there an electrical service
disconnect within sight of the
installed machine? Has the
voltage been checked, and
compared to nameplate
requirements?
3. Have all the plumbing
connections been made and
checked for leaks?
4. Has the machine and bin been
leveled?
5. Is there a minimum of 6"
clearance at the rear, left, right
and above the machine for
proper service access?
6. Is the water pressure a
minimum of 20 psig?
7. Has the machine been
secured to the bin?
8. Is there a water shut off valve
installed near the machine?
9. Is the remote condenser
installed per local building codes,
and in a place where it has
adequate ventilation and minimal
solar heat gain?
10. Has all shipping material and
literature (inside the front panel)
been removed from the units?
121 Have the remote condenser
and precharged lines been
properly installed?
12. Has the electrical connection
between the ice maker and the
condenser been made?
13. Verify that the master
switches are in the OFF position.
14. Switch on the electrical
power.
15. Refer to Pre-Start instructions, the next page.
ROOF
HOLES
SEALED?
POWER
SUPPLY?
LEVELED?
PLUMBING?
REMOTE
CONDENSER
SECURED?
NME1850R & FME2400R
January 1995
Page 12