AutoIQ Controller:
Indicator Lights:
•
Bin Full:
On when bin is full, goes on and
off as ice falls during a harvest cycle.
•
Freeze:
On when the unit is in the Freeze
cycle, blinks when a freeze cycle is pending.
•
Harvest:
On when the unit is in the Harvest
cycle.
•
Clean:
On when the unit is in the Clean
cycle.
•
Off:
On when the unit has been switched off,
blinks when the machine is preparing to shut
off.
•
Water Error:
On when the controller has
identified a problem with the water system.
•
Refrigeration Error:
On when the controller
has identified a problem with the
refrigeration system.
Cycle Definitions:
•
Freeze:
The refrigeration system is
operating to remove heat from the
evaporators. The compressor, remote fan
motor and water pump are ON.
•
Harvest:
The refrigeration and water
systems are operating to harvest the ice
cubes. While the compressor and fan motors
are on for the full cycle, the water pump will
be off at the beginning and the inlet water
valve will switch off before the end.
•
Clean:
Water valve opens to fill the
reservoir. The Water pump starts. The Clean
indicator light is switched ON. A manually
initiated rinse cycle flushes the system.
CME506R, 656R, 806R: AutoIQ Cubers
January 2000
Page 14
1
2
3
4
5
6
7
8
9
BIN FULL
FREEZE
HARVEST
CLEAN
OFF
WATER
REFRIGERATION
Reservoir Water
Level Sensor
Bin Control Sensor
Bin Control Sensor
Reservoir & Discharge
Line Thermistors
Low Voltage In/out
Water Valve
Hot Gas Valve
Contactor Coil
Stacking
Future Use
Factory Use
Push Button
Control Switches
Hi Voltage In/out
Water Pump
Air Cooled Fan Motor
Indicator Lights:
Diagnostic Lights
Содержание CME506R
Страница 42: ......