BC0530 Service Manual
March 2020
Page 19
ALARM
CLEAN
MAKE ICE
FILL
FREEZE
LOWER
HARVEST
RAISE
HI WATER
LOW WATER
OVERFLOW
ARM UP
PLATE UP
ARM DOWN
BIN FULL
FULL RINSE
POWER
WATER LEVEL SENSOR
PROGRAMMING PORT
RESET
EVAPORATOR TEMP ADJUSTMENT
EVAPORATOR PROBE
BIN PROBE
BIN FULL ADJUSTMENT
SWITCH INPUT PORT
AC OUTPUTS
DUAL EVAPORATOR JUMPER
WATER RINSE JUMPER
FACTORY USE ONLY!
Machine Status:
Displays the position of the Ice/
Clean switch or an Alarm.
Sequence
: Displays the current stage of the ice
making process.
Input Status
: Displays the status of the individual
sensors for the ice making process.
Fault Codes:
The electronic control will monitor
for the following conditions and shut down the ice
machine as required to prevent damage to the
equipment.
>2
If the water tray automatically cycles 3 times
in a row due to a water plate obstruction the controller
will shut down the ice maker and provide LED fault
indicators.
After 3 consecutive failed attempts at raising the
water plate, the machine will defrost in 5 minutes then
try again. A 2 will flash during the 5 minute defrost.
Machine will shut down if it fails after this defrost
period.
>3
Flashes after 3 consecutive cycles over 35
minutes, But will not shut down the machine. Stops
flashing once a cycle is under 35 min.
Controller