10.
The parameters already set before the machine is shipped out from
factory, users are no need to change.
11.
Scotle HR460C can monitor the whirling speed of the cooling fan for top and
bottom hot air heater. And the minimum whirling speed can be set. If the
fan stop working or less than the minimum setting value, and the actual
temperature of top and bottom hot air is more than 300 degrees, the
machine will stop heating immediately..
12.
The rework system can automatically set the alarming time in advance.
If set 10s, the machine will buzz 10s before the heating process finished.
And the machine enters into cooling status, and the main interface will
display the failure point to help operator resolve the problem soon.
Note:
If the BGA rework station alarms caused by any failure, all function
buttons will be locked until after the failure is resolved, then power off and
power on, you can use it again.