Shenzhen SCOTLE Technology
-----------------------------------------------------------------------
Email:[email protected] Tel:86075589378931
http://www.scotle.com/
------------------------------------------------------------------------------------------------
and input the name then
. Also you can save it by touching
to save the current profile certified.
Back to touch Start, the BGA rework machine will run the certified
temperature profile and meanwhile the previous profile will be deleted.
8.
Generally speaking, the top target parameters are all ran or the top ramp up
slope is 0, then the heating process is finished and the machine stop
running and begin buzzle. If the cooling system and vacuum system already
set, they will begin to work.
9.
Once you touch STOP
during the heating process, the BGA
rework station stop heating Immediately.
Once you touch
during the heating process, the button will
flickering to let the machine run the current temperature constantly without
any change. And touch
again, the machine will proceed the
normal heating process.