background image

 

 

 

Disclaimer 

 

The  intellectual  property  right  on  the  manual  belongs 

to Dragon Laboratory Instruments Limited (hereinafter 
referred to as “the Company”), i.e. relevant copyright 

belongs to the company. 

 

Products  of  the  company  are  under  the  patent 

protection  of  China  and  other  countries  and  regions 

(including  obtained  patents  and  patents  being  applied 

for). 

 

We  elaborately  prepared  the  manual  in  the  attitude  of 
being responsible for the users. But we can’t guarantee 

that the contents of the manual are fully correct. If any 

occasional  or  subsequent  loss  is  caused  by  the  use  of 

the Manual, the company will not be liable for this at 

all. 

 

The  manual  is a pure technical  document, free of  any 

implication  or  oblique  hint  of  any  third  party. 
Moreover,  we  won’t  be  liable  for  any  user’s 
misunderstanding upon the printer’s error(s). 

 

The  company  and  any  of  the  company’s  employees 
will  not  bear  any  liability  for  direct/indirect  loss  of 

information or stop of business (if any) caused by the 

information of the manual or the product it mentions. 

 

The company reserves the right to change specification 

and price of the product. 

 

If any information of the manual changes, we will not 

notify this otherwise. 

 

The manual and any content of it must not be copied, 

abstracted  or  modified  in  any  form  without  the 
company’s written approval in advance. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание SCI100-S

Страница 1: ...a at t to o or r r Operation Instructions LED Digital Rotary Evaporator Please carefully read the Instructions and use the product safely under the direction of the Instructions If any information of...

Страница 2: ...he use of the Manual the company will not be liable for this at all The manual is a pure technical document free of any implication or oblique hint of any third party Moreover we won t be liable for a...

Страница 3: ...cation 5 3 Inspection 6 3 1 Open package inspection 6 3 2 Package list 6 4 Control and display 6 4 1 Control 6 4 2 Display 9 5 Installation and testing 11 5 1 Installation 11 5 2 Testing 14 6 Fault di...

Страница 4: ...nty card Description of problem phenomenon The method and operating steps you have undertaken to resolve the problem Your contact details including telephone number fax number and email address Warran...

Страница 5: ...obiological medium might cause damage to the operator Place the instrument on a stable clean antiskid dry and fireproof table surface Make sure there is sufficient space above the instrument and the g...

Страница 6: ...rantee the operational safety Please refer to the operating instructions for heating kettle Please refer to the operating instructions for optional accessories Please use this instrument in a closed f...

Страница 7: ...flask and glass assembly might become hot in the operation process and remain hot for a while after stop of the operation Before further operation please let each part cool down Note be careful to av...

Страница 8: ...es are protected from extrusion and collision Only professional repairman may open the instrument 2 Scope of application This instrument is designed for such application environments as schools labs a...

Страница 9: ...e contact supplier or manufacturer Caution 1 If you find any visible damage on the product please don t connect the product to power supply 3 2 Package list Name Qty Main unit 1 Heating bath 1 Power c...

Страница 10: ...Rotary Evaporator 7 Fig 2 Fig 3 Main unit three in one switch Heating bath power interface Heating bath power switch...

Страница 11: ...erse rotation interval time Turning the adjustment knob can set the intermittent left and right rotation time within the range of 1 999 sec When set to 0 sec the instrument rotates forward only Adjust...

Страница 12: ...es the real time speed Fig 6 This interface indicates the real time speed Turn the adjustment knob to set the speed and press the adjustment knob to start the instrument The rotation speed can be chan...

Страница 13: ...get temperature of the heating bath After setting by pressing the knob the heating indicator is on and the heating process begins In the heating process the target temperature can be changed by turnin...

Страница 14: ...Fig 11 Place the main unit on a flat tabletop and squeeze the handle switch a to lift it to the highest position Fig 12 Tighten the screw b by hand adjust the angle of the motor head and tighten the...

Страница 15: ...mount the evaporating tube in place and rotate the locking device d clockwise for locking Mount the seal ring Fig 13 and Fig 14 Fig 14 Fig 15 Mount the condenser f Fig 15 and Fig 16 Slide the locking...

Страница 16: ...ry Evaporator 13 Fig 16 Fig 17 Mount the fixing device for the vertical condensation glass assembly Fig 17 Fig 18 Piping connection Fig 18 f Condensate inlet Vacuum tube interface g h g Condensate out...

Страница 17: ...90 under the water bath mode Press the temperature adjustment knob to start heating Squeeze the handle switch to place the evaporating flask into the heating bath Press the adjustment knob to start ro...

Страница 18: ...supply until all surfaces are dry If liquid or moist solid enters the product please disconnect the power supply quickly and leave off and contact the manufacturer supplier for more advice Keep the p...

Страница 19: ...ower W 45 1010 Motor DC brushless Speed range rpm 20 200 Display LED Temperature range C Room temperature 180 Temperature control accuracy C 1 oil 3 Lifting method Manual Lifting travel mm 110 Forward...

Страница 20: ...Rotary Evaporator 17 External dimension W x D x H mm 440 320 450 300 300 240 Weight kg 7 3 Allowable ambient temperature C 5 40 Allowable RH 80 DIN EN60529 protection class IP20 USB Yes...

Страница 21: ...SCILOGEX LLC 1275 Cromwell Ave Suite C6 Rocky Hill CT 06067 USA Tel 1 860 436 9221 Fax 1 860 436 9745 info scilogex com www scilogex com...

Отзывы: