novoSchwank shape U
50
Vers
ion 013 nov
o
sha
pe U 38
/19
INT
T
e
c
hnic
a
l sp
ec
ific
at
io
n sub
ject
to c
hang
e
Reflector elongation
Vertical elongation of reflectors b=415 mm for
thermal protection.
The numbers of reflector elongation [single sheets]
is depending on required protection [one side
both side, protection length] and the power of
the radiant heater.
Delivery scope
The required reflector elongation can be
compiled depending on the extent of necessary
protection out of the following basic elements:
02676300
reflector elongation L= 3000 mm
02676310
reflector elongation L= 3000 mm
End segment U [only for for end segment
heater shape U with turn around box]
02676320
reflector elongation L= 1500mm
Assembly instruction
1.
Complete assembling heater with reflectors
complete [see chapter 9, page 21-24].
2.
Mount bolts with spacer sleeves and mounting
brackets
A
at required positions [Fig. 48].
3.
If required fasten mounting bracket
B
to turn
around box by losing 4 lower hex. nuts M8,
placing mounting bracket on tube flanges and
fastening hex. nuts [Fig. 50].
4.
Place reflector elongation
C
on mounting
brackets
A
and bolt them together with
reinforcement plates
D
[self-securing nut M8]
[Fig. 48].
5.
Bolt reflector elongation loosely together at
overlapping by means of M8 bolt/nuts.
6.
In case of one-sided load on bolts mount
additional mounting bracket
E
[Fig. 49].
7.
If using mounting bracket
B
mount safety lock
F
[Fig. 50].
In the case of heaters with end reflector
the last hanger at the burner side must be
placed at the junction of the reflector
and the end reflector
.
Fig. 48: Mounting of reflector elongation on hanger
Fig. 49: Mounting of reflector elongation on first hanger with
additional bracket
Fig. 50: Mounting of reflector elongation on turn around box
with safety lock
A
D
C
E
B
F