novoSchwank shape U
51
Version 013 nov
o
sha
p
e U 38/1
9_
IN
T Techni
cal
s
p
e
c
ifi
c
a
tio
n s
ub
jec
t t
o
chan
g
e
Set angled mounting tubes
Bracket to ensure form and position of reflectors
when the heater is mounted angled [>15°].
Mount bracket to at each junction point
reflector/reflector, not at reflector end caps.
Article number for set shape U: 12671480
Delivery scope
Mounting set consists of:
Bracket
mounting material
Assembling instruction
1.
Assembling and mounting of tubes complete
without [see chapter 9, page 21-24].
2.
Lay first reflector on turnaround box and first
hanger, fix it at turnaround box with two
screws.
3.
Fix angled bracket
G
with screws and nuts M8
at first hanger, bracket under reflector.
4.
Put on next reflector, reflectors are fixed to
another by 3 screws/nuts M5, middle screw
through angled bracket.
5.
Further assembling as described in chapter 9,
page 21-24.
Fig. 51, 52: Assembling order reflector elongation
Gas filter groups
To avoid technical problems with the gas
combination valves which are caused by
pollution of dust or rust coming out of the gas pipe
have to be mounted a
gas filter group ¾“ [gas premounted
double nipple] for each tube heater 55S U.
For tube heaters 20S U – 35S U a similar gas filter
group ½“ has to be ordered in case the gas pipe
is made of black steel [welded].
Assembly instruction
Direct installation between flexible gas pipe and
valve burner kit, with a slight radial slope for better
cleaning the filter bottom! In case of strong
polluted filter pad use the corresponding spare
part set for gas filter.
Pay attention to the flow direction of the filter!
Fig. 53: Mounted gas filter group at tube heater
gas filter group
for 20S U – 35S U
Rp ½“ Art.-no: 192 0756 0
gas filter group
for 45S U – 55S U
Rp
3
/
4
“ Art.-no: 192 0757 9
G