4 Troubleshooting
EN Floor grinding machine DSM 250
17
The power socket serving as the electric supply
should be installed and provided with mains cur
rent according to local regulations!
Risk of injury from inadvertent starting of the
machine!
Before plugging in the power plug, make sure
that the safety switch on the machine is
switched off, i.e. not pressed in.
10. Plug power plug [16, Fig. D] into the socket (use
extension cable if necessary).
The machine is ready for operation.
3.2 Grinding
Risk of damage and injury from uncontrolled
movement of the machine!
Before pressing the safety switch, the machine
has to be held firmly by the handle of the guide
bar.
1.
If necessary, feed in water onto surfaces that
are to be ground wet.
2.
Hold the machine by the handle [1, Fig. A] of the
guide bar.
3.
Press the safety switch [2, Fig. A] on one or
both sides and hold tight.
The surface to be ground can now be machined.
Depending on the application, the machine
needs to be retrofitted (
!
Pos. 7).
3.3 Switching the machine off
Observe the safety instructions in Chapter 2!
Risk of injury from grinding plate still rotating
after the machine is switched off!
Only switch off the machine with the ETX dia
mond tools resting on the floor.
The grinding plate can otherwise still rotate idly
(run-on) for several seconds after being
switched off or the safety switch is released.
—
Release safety switch [2, Fig. A] on both sides.
The machine is switched off.
Risk of injury from high voltage!
When the safety switch is released, the machine
still has voltage.
To de-energize the machine, pull the power plug
from the line to the voltage supply.
4 Troubleshooting
Only suitably knowledgeable, qualified profes
sional technicians may perform repairs on the
machine.
Malfunction
Cause
Rectification
Machine will not start.
Connecting cable for the voltage sup
ply is not properly connected with the
power socket.
Plug power plug [16, Fig. D] into the
socket.
Connecting cable is defective.
Replace connecting cable.
Safety switch is defective.
Replace safety switch.
Grinding pattern is uneven.
ETX diamond tools are loose.
Fasten ETX diamond tools.
ETX diamond tools are damaged or
worn.
Replace ETX diamond tools.
Содержание 713564