Assembly
20
03.00 | NSL3 | VERO-S quick-change pallet system | en | 1155408
Clamping range
NSL3 150-V1-T
NSL3 200 / NSL3
200-V1-T
NSL3 400
NSL3 600
NSL3 800
A, I
B, C, J, K
B, E, J, M
B, D, G, J, L, O B, D, F, H, J, L,
N, P
Note
The clamping range of the NSL3 300-200 is based on the clamping
scheme of the NSL3 400. Here, optionally available BRR50 clamp
blanks are to be attached to four clamping points distributed
evenly on the round outer diameter.
Cylindrical clamps are versatile fixturing elements
The mounting holes are machined by the customer
Flexible mounting possibilities for common T-nut distances
Mounting clamp blanks
Alternating ventilation for the clamping modules when
connecting and disconnecting the air supply at the clamping
station
When connecting the clamping station, it must be taken into
consideration that complete ventilation of the piston chambers in
all clamping modules during the locking process is only possible via
the air connection. For safe pressure ventilation, use the
appropriate valves, shut-off valves with discharge or sealing
nipples with air bleed screw.
NSL3 clamping stations without turbo function
For NSL3 clamping stations without turbo function, ventilation of
the clamping modules occurs as a result of pressure applied to the
unlocking connection via its own ventilation hole along the bottom
of the base plate of the clamping station used. When setting up a
clamping station without turbo function on the machine table,
make sure that the vented compressed air is able to escape