Maintenance and care
01.00|NSL mikro 50-13 1425873|en
29
•
Check the clamping stations at regular intervals (at least every
two weeks or after 1000 clampings). The system is functioning
correctly if the clamping slides move smoothly at minimum
system pressure (5 bar) and open completely.
•
Carry out regular visual/functional checks. In case of visible
damage or signs of malfunction, shut down the quick-change
pallet system immediately. The system may only be started
again once the faults have been corrected, for instance by
replacing a damaged module.
Control of proper function
For the functional test, the proper functioning of the quick-change
pallet systems should be tested.
The systems is working perfectly if:
•
the clamping slide moves smoothly at minimum system
pressure (5 bar).
•
the desired functions correspond to the symbol on the
clamping station housing.
•
the clamping system shows no signs of leaking.
5.2