Maintenance and care
Manual lubrication
• Press grease either into the grease nipples at
the side or front of the respective supply line
(6/7).
• Only lubricate in the open position.
• After greasing, run through the complete
stroke several times.
• Grease to be used and lubrication
intervals.
Size
Grease quantity (strokes per grease nipple)
64
1
100
2
140
2
160
2
200
2
250
3
315
4
Central lubrication
• To use central lubrication, the set-screws of
the factory sealed connections (6, 7) must be
removed.
• For proper lubrication, both supply lines
must be connected.
• The central lubrication system must be
suitable for greases of NLGI 2 classification.
• Only lubricate in the open position.
• After greasing, run through the complete
stroke several times.
• Grease to be used and lubrication
intervals,
Size
Grease quantity (per connection) [cm³]
64
2
100
4
140
4
160
4
200
4
250
4
315
6
31