5.3 Installation
The connection dimensions can be found in the respective drawings in the current catalog or in
our CAD data service on the Internet (link under www.schunk.com).
5.3.1
Air connection
CAUTION!
-
Switch off the power supply during installation of the quick-change system.
-
Comply with the safety instructions in Chapter 1.3, page 3.
Requirements
Pressure medium
compressed air
Requirement for quality of the
compressed air
to DIN ISO 8573-1:
6 4 4
Hose connection
Connect the pressure hose to the mounted air connection.
Max. Betriebsdruck
6 bar
Type SWS-I
011
/10/
Thread diameter of air connection
M5
Table 3: Air connection threads
Figure 3: Air connection (radial or axial output)