Troubleshooting
30
02.01|RST-P 060 / 087|en
Signal for piston position or zero point cycle ring monitoring
missing?
Possible cause
Corrective action
IN sensor (zero point monitoring) adjusted
incorrectly
MMS sensor (piston position monitoring)
adjusted incorrectly
Proximity switch defective or set incorrect. Replace sensor
Cable breakage
Replace connection cable for sensor
Module hitting in end positions?
Possible cause
Corrective action
Check stroke reduction dimensions
•
ge 18)
•
Shock absorber defective
The exhaust air throttle is defective
Replacing the exhaust air throttle
Swiveling speed to high
Check swiveling time and adjust with ex-
haust air throttles as necessary
Page 15)
.
Useful load swings to end position?
Possible cause
Corrective action
Swiveling speed to high
Check swiveling time and adjust with ex-
haust air throttles as necessary
Page 15)
Shock absorber not well adjusted
Unfavorable installation
Check design
RST-P type too small
User larger RST-P type
9.3
9.4
9.5