Assembly and settings
02.01|RST-P 060 / 087|en
17
1 Set cycle ring to zero point position. Marking groove on the
cycle ring is in agreement with the marking holes in the
switching plate and bearing ring (
☞
arrows).
2 Remove the cap from the connection thread.
3 Screw sensor (1) into the thread until the signal is present at
the output.
4 Lock sensor into place with a counter-nut.
MMS sensor attachment
NOTICE
Risk of damage to the sensor during assembly!
•
Observe a maximum tightening torque of 10 Ncm for the set-
screws.
Fig. 6
MMS sensor attachment
For monitoring of the two end positions of the piston, one sensor
each is installed.
1 Turn sensor (2) into the groove (1 - 4).
2 Pressurize piston at connection A or B to ensure that it is in
3 Adjust the sensor (2) to piston position and lock into place us-
ing an Allen key.
4 If need be, repeat the procedure with the second sensor and
the opposing piston position.
7.3.2