Assembly
09.00 | PWG-plus | Assembly and operating manual | en | 389495
25
Assembly of IN 80
PWG-plus 200-240
mounting kit
Ø
Fasten screw (5) and nut (1) to brackets (2).
Ø
Fasten bracket (2) to the housing using screws (4) and washers (3).
Ø
Fasten the control cams (6) to the rotary bolt using the screws
(8) place lock washers (7) between control cams and screw
head.
Assembly of IN 80
proximity switch
The switching points of the "open" and "closed" positions must be
set by the customer himself.
Gripper open:
Ø
Set the gripper to the "Open" position.
Ø
Undo the screws (6).
Ø
Turn the control cam (5) so that the lug is parallel to the bracket (2).
Ø
Fasten the control cam by tightening the screw (6).
Ø
Push the proximity switch (1) to the stop of the bracket (2).
Ø
Fasten the proximity switch by tightening the screw (3) in the
bracket.