Assembly and installation
20
01.00 | PCFC | Assembly and Operating Manual | en | 1454631
Pneumatics
connection diagrams
NOTE
Depending on the application, only one of the retract and extend
air connections may be necessary.
Display
Display
PCFC
Air purge connection
(max. 2 bar)
Retract the
compressed air
line
Extend the compressed
air line
Distributor
Air connection
4.1 bar
External regulator (1-4.1 bar)
External regulator (1-4.1 bar)
Pneumatic connection diagram for application without gyro sensor
PCFC
Retract the
compressed air line
Extend the
compressed
air line
Distributor
Air connection
4.1 bar
External programmable regulator
(1-4.1 bar)
External programmable regulator
(1-4.1 bar)
Regulator Kit
Air purge
connection
(max. 2 bar)
Pneumatic connection diagram for application with gyro sensor