Assembly and installation
5.2.2 Pneumatic connection
NOTE
• Observe the requirements for the compressed air supply,
• Use a regulator with venting for better regulation of the
compressed air.
1
Air purge connection
2
Compensation air connection (extension)
3
Compensation air connection (retraction)
Item Mounting
PCFC
1
Thread
M5
Hose connection [mm]
4
2
3
Thread ["]
G1/4
Hose connection [mm]
10
19