Assembly
104
05.00 | LDT | Montage- und Betriebsanleitung | en | GAS360927
6 Assembly
6.1 Mechanical connection of the module
WARNING
Risk of injury when the machine/system moves unexpectedly!
Switch off power supply.
DANGER
Danger from voltage!
Touching live parts can be deadly.
•
Switch off the power supply before any assembly, adjustment
or maintenance work and secure against being switched back
on again.
•
Only qualified electricians my carry out electrical installation
work.
•
Disconnect the converters from the power supply.
•
The intermediate circuit capacitors must be discharged.
•
Note the correct sequence for connecting cables (first the
grounding cable, then conductors).
DANGER
Danger to life due to strong magnetic fields even in a shut-down
state.
The secondary parts integrated in the product are high-
performance permanent magnets. Medical devices such as
pacemakers or hearing aids may be destroyed or cause
malfunctions.
•
Keep a sufficient minimum distance to the secondary part if
you have a pacemaker or are wearing hearing aids or the like.
Evenness of the
mounting surface
The values apply to the whole mounting surface to which the
product is mounted.
Requirements for evenness of the mounting surface (Dimensions in mm)
Edge length
Permissible unevenness
< 100
< 0.02
> 100
< 0.05
Содержание LDT Series
Страница 1: ...Montage und Betriebsanleitung Assembly and Operating Manual...
Страница 4: ...2 05 00 LDT Montage und Betriebsanleitung GAS360927 deutsch 3 english 78...
Страница 5: ...Original Betriebsanleitung Montage und Betriebsanleitung LDT Linearmotorachse...
Страница 44: ...Montage 42 05 00 LDT Montage und Betriebsanleitung de GAS360927 Pneumatikplan Pneumatikplan f r Haltebremsen...
Страница 80: ...Translation of the Original Operating Manual Assembly and Operating Manual LDT Linear motor shaft...
Страница 119: ...Assembly 05 00 LDT Montage und Betriebsanleitung en GAS360927 117 Pneumatic diagram Pneumatic diagram for holding brake...
Страница 155: ......