Assembly
28
03.00 | GSM-W | Assembly and operating manual | en | 389108
5.3.6 Assembly and setting of the MMS-P 22
Position and installation of the magnetic switch MMS-P
1
Sensor MMS-P
(left groove)
Monitoring gripper position 1 and gripper
position 2 in the left rotating angle end
position (signals SGL1 and SGL2)
2
Sensor MMS-P
(right groove)
Monitoring gripper position 1 and gripper
position 2 in the right rotating angle end
position (signals SGR1 and SGR2)
3
Stop for MMS-P Determining the clamping position of the
MMS-P sensor
Monitoring GSM locations/positions/end positions:
SGL1: left rotating angle end position, gripper position 1
SGL2: left rotating angle end position, gripper position 2
SGR1: right rotating angle end position, gripper position 1
SGR2: right rotating angle end position, gripper position 2
By each of the two sensors MMS-P, 2 gripper positions can be
monitored. If the gripper is in a third position, the rotation angle
end position can only be monitored by additional sensors.
• The left rotating angle end position is always reached, when a
swichting point of the sensor of the left groove (SGL1 or SGL2) is
active.