8 Maintenance
8.1 Notes
Original spare parts
Use only original spare parts of SCHUNK when replacing spare and
wear parts.
Replacement of the housing and base jaws
The cover housing (35), fingers (3), and needle rollers (13, 14, 15)
are adapted to each other. To replace these parts, send the
complete module together with a repair order to SCHUNK or order
the housing with base jaws as a set.
NOTICE
The needle rollers are suitable only for this product and cannot
be replaced with needle rollers belonging to another product of
the same type and size.
8.2 Maintenance and care intervals
NOTICE
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
•
Reduce the lubricant intervals accordingly.
Maintenance and care intervals GSM-W
Size GSM-W
32 - 64
Interval [Mio. cycles]
2
Maintenance and care intervals DKM
Size DKM
40 / 64
Interval [Mio. cycles]
2
Maintenance and care intervals FAN
Size FAN
40 / 64
Interval [Mio. cycles]
2