background image

 5 

7. 

FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE.

A SPARK NEAR THE BATTERY MAY CAUSE A 

BATTERY EXPLOSION. TO REDUCE THE RISK 

OF A SPARK NEAR THE BATTERY:

7.1 

Check the polarity of the battery posts. The 

POSITIVE (POS, P, +) battery post usually has a 

larger diameter than the NEGATIVE (NEG, N, -) post.

7.2 

Attach at least a 24-inch (61 cm) long 6-gauge (AWG) (13.29 mm

2

) insulated battery 

cable to the NEGATIVE (NEG, N, -) battery post.

7.3 

Connect the POSITIVE (RED) charger clip to the POSITIVE (POS, P, +) post of the battery.

7.4 

Position yourself and the free end of the cable you previously attached to the NEGATIVE 

(NEG, N, -) battery post as far away from the battery as possible – then connect the 

NEGATIVE (BLACK) charger clip to the free end of the cable.

7.5 

Do not face the battery when making the final connection. 

7.6 

Connect charger AC supply cord to electrical outlet.

7.7 

When disconnecting the charger, always do so in the reverse order of the connecting 

procedure and break the first connection while as far away from the battery as practical.

7.8 

A marine (boat) battery must be removed and charged on shore. To charge it onboard 

requires equipment specially designed for marine use.

8. 

GROUNDING AND AC POWER CORD CONNECTIONS

RISK OF ELECTRIC SHOCK OR FIRE.

8.1 

This battery charger is for use on a nominal 120-volt circuit. 

It will have either a two-prong plug or a three-prong, grounded plug. 

8.2 

If it has a three-prong plug, the charger must be grounded 

to reduce the risk of electric shock. The plug must be plugged into 

an outlet that is properly installed and grounded in accordance 

with all local codes and ordinances. The plug pins must fit the receptacle (outlet). Do not 

use with an ungrounded system.

8.3 

Never alter the AC cord or plug provided – if it does not 

fit the outlet, 

have a proper grounded outlet installed by a qualified electrician. An improper 

connection can result in a risk of an electric shock or electrocution. 

8.4 

Recommended minimum AWG size for extension cord:

• 

100 feet (30.5 meters) long or less – use an 18 gauge (0.82 mm

2

) extension cord.

• 

Over 100 feet (30.5 meters) long – use a 16 gauge (1.31 mm

2

) extension cord.

9. 

ASSEMBLY INSTRUCTIONS

Remove all cord wraps and uncoil the cables prior to using the battery charger. 

10.  CONTROL PANEL 

Digital Display 

The Digital Display gives a digital indication of % of charge or voltage, depending on the 

Display Mode chosen.

Display Mode Button 

Use this button to set the function of the Digital Display to one of the following:

• 

Battery % –

 The Digital Display shows an estimated charge percent of the battery 

connected to the charger battery clamps.

• 

Voltage –

 The Digital Display shows the voltage at the charger battery clamps in DC volts.

Содержание SC-1000A

Страница 1: ...621 5485 Email services schumacherelectric com Web www batterychargers com NO LO DEVUELVA ESTE PRODUCTO A LA TIENDA Contacte Servicios al Cliente para asistencia Tel fono 800 621 5485 Correo Electr n...

Страница 2: ...nded attachments Use of an attachment not recommended or sold by Schumacher Electric Corporation may result in a risk of fire electric shock or injury to persons or damage to property 1 4 To reduce th...

Страница 3: ...d protective clothing Avoid touching your eyes while working near the battery 2 9 If battery acid contacts your skin or clothing immediately wash the area with soap and water If acid enters your eye i...

Страница 4: ...2 Stay clear of fan blades belts pulleys and other parts that can cause injury 6 3 Check the polarity of the battery posts The POSITIVE POS P battery post usually has a larger diameter than the NEGAT...

Страница 5: ...FIRE 8 1 This battery charger is for use on a nominal 120 volt circuit It will have either a two prong plug or a three prong grounded plug 8 2 If it has a three prong plug the charger must be grounde...

Страница 6: ...uched together Battery Connection Indicator If the charger does not detect a properly connected battery the CONNECTED red LED will not light Charging will not begin if the CONNECTED red LED is not on...

Страница 7: ...Limit If no button is pressed within 15 minutes after the battery charger is first powered up the charger will automatically switch from tester to charger if a battery is connected In that case the c...

Страница 8: ...may also be faulty This will happen if the battery did not reach full charge within 48 hours May be due to a very large battery or a bank of batteries requiring more power than the charger can deliver...

Страница 9: ...er is equipped with an auto start feature It will not supply current to the battery clips until a battery is properly connected Unlike traditional chargers the clips will not spark if touched together...

Страница 10: ...s no other warranties including but not limited to express implied or statutory warranties including without limitation any implied warranty of merchantability or implied warranty of fitness for a par...

Страница 11: ...a limitada expresa y el productor no autoriza ni otorga a alguien a realizar alguna otra obligaci n No existe ninguna otra garant a m s que la descrita en el manual del due o La tarjeta de garant a de...

Страница 12: ...12...

Страница 13: ...ga el cargador a la lluvia o a la nieve 1 3 Utilice solamente accesorios recomendados El uso de un accesorio no recomendado o suministrado por Schumacher Electric Corporation puede provocar riesgo de...

Страница 14: ...a para cargar bater as de pila seca que por lo general se utilizan con artefactos dom sticos Estas bater as podr an explotar y provocar lesiones a personas o da o a la propiedad 2 5 NUNCA cargue una b...

Страница 15: ...rma 5 PRECAUCIONES DE CONEXI N EN CC 5 1 Conecte y desconecte los ganchos de salida C C s lo despu s de haber desconectado el enchufe de C A del tomacorriente el ctrico 5 2 Sujete los ganchos a la bat...

Страница 16: ...e en posici n frontal a la bater a al realizar la conexi n final 7 6 Conecte el cond n de alimentaci n del cargador de CA al tomacorriente 7 7 Al desconectar el cargador siempre h galo en forma invers...

Страница 17: ...de auto marinas y de ciclo profundo No recomendable para uso industrial 10A 12A 15A Proporci n de Carga grande Para bater as de auto marinas y de tipo marino No se destina para las aplicaciones indus...

Страница 18: ...podr a llevar hasta 8 horas Si la desulfataci n no tiene xito se anular la carga Vea la secci n de Carga Anulada Finalizaci n de carga La finalizaci n de la carga se indica por medio del LED CARGADO...

Страница 19: ...hasta que el LED del ndice de carga se apague 12 INSTRUCCIONES DE MANTENIMIENTO 12 1 Despu s de usar y antes de realizar mantenimiento desenchufe y desconecte el cargador de la bater a ver secciones...

Страница 20: ...plena carga dentro de 36 horas Puede ser a causa de una bater a muy grande o banco de bater as que requiere m s fuerza de lo que el cargador puede proveer en 36 horas Reponga el corcel quitandolo Esc...

Страница 21: ...r Y corrija todas las conexiones El cargador no enciende a n cuando hay buena conexi n El tomacorriente est muerto Mala conexi n el ctrica Revise los fusibles del interruptor de circuitos que alimente...

Страница 22: ...o y da ino para una bater a tratar de forzar dentro de ella un amperaje mayor de lo que puede usar eficazmente en la recarga 15 3 Cuando se presenta un PROBLEMA DE OPERACI N DESCONOCIDO s rvase leer e...

Страница 23: ...das a t tulo enunciativo las garant as expresas impl citas o legales incluidas a modo de ejemplo las garant as impl citas de comerciabilidad o adecuaci n a un fin espec fico Asimismo el Fabricante no...

Отзывы: