CHARGER LOCATION

RISK OF EXPLOSION AND CONTACT WITH 

BATTERY ACID.

4.1 

Locate the charger as far away from the 

battery as the DC cables permit.

4.2 

Never place the charger directly above the 

battery being charged; gases from the battery will corrode and damage the charger.

4.3 

Do not set the battery on top of the charger.

4.4 

Never allow battery acid to drip onto the charger when reading the electrolyte specific 

gravity or filling the battery.

4.5 

Do not operate the charger in a closed-in area or restrict the ventilation in any way.

5. 

DC CONNECTION PRECAUTIONS

5.1 

Connect and disconnect the DC output clips only after removing the AC plug from the 

electrical outlet. 

5.2 

Attach the clips to the battery and chassis, as indicated in sections 6 and 7.

6. 

FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE.

A SPARK NEAR THE BATTERY MAY CAUSE A 

BATTERY EXPLOSION. TO REDUCE THE RISK 

OF A SPARK NEAR THE BATTERY:

6.1 

Position the AC and DC cables to reduce the 

risk of damage by the hood, door and moving or hot 

engine parts. NOTE: If it is necessary to close the 

hood during the charging process, ensure that the hood does not touch the metal part of 

the battery clips or cut the insulation of the cables.

6.2 

Stay clear of fan blades, belts, pulleys and other parts that can cause injury.

6.3 

Check the polarity of the battery posts. The POSITIVE (POS, P, +) battery post usually 

has a larger diameter than the NEGATIVE (NEG, N, -) post.

6.4 

Determine which post of the battery is grounded (connected) to the chassis. If the 

negative post is grounded to the chassis (as in most vehicles), see step 6.5. If the 

positive post is grounded to the chassis, see step 6.6.

6.5 

For a negative-grounded vehicle, connect the POSITIVE (RED) clip from the battery 

charger to the POSITIVE (POS, P, +) ungrounded post of the battery. Connect the 

NEGATIVE (BLACK) clip to the vehicle chassis or engine block away from the battery. 

Do not connect the clip to the carburetor, fuel lines or sheet-metal body parts. Connect 

to a heavy gauge metal part of the frame or engine block.

6.6 

For a positive-grounded vehicle, connect the NEGATIVE (BLACK) clip from the battery 

charger to the NEGATIVE (NEG, N, -) ungrounded post of the battery. Connect the 

POSITIVE (RED) clip to the vehicle chassis or engine block away from the battery. Do 

not connect the clip to the carburetor, fuel lines or sheet-metal body parts. Connect to a 

heavy gauge metal part of the frame or engine block.

6.7 

Connect charger AC supply cord to electrical outlet.

6.8 

When disconnecting the charger, disconnect the AC cord, remove the clip from the 

vehicle chassis and then remove the clip from the battery terminal.

Содержание SC-1000A

Страница 1: ...621 5485 Email services schumacherelectric com Web www batterychargers com NO LO DEVUELVA ESTE PRODUCTO A LA TIENDA Contacte Servicios al Cliente para asistencia Tel fono 800 621 5485 Correo Electr n...

Страница 2: ...nded attachments Use of an attachment not recommended or sold by Schumacher Electric Corporation may result in a risk of fire electric shock or injury to persons or damage to property 1 4 To reduce th...

Страница 3: ...d protective clothing Avoid touching your eyes while working near the battery 2 9 If battery acid contacts your skin or clothing immediately wash the area with soap and water If acid enters your eye i...

Страница 4: ...2 Stay clear of fan blades belts pulleys and other parts that can cause injury 6 3 Check the polarity of the battery posts The POSITIVE POS P battery post usually has a larger diameter than the NEGAT...

Страница 5: ...FIRE 8 1 This battery charger is for use on a nominal 120 volt circuit It will have either a two prong plug or a three prong grounded plug 8 2 If it has a three prong plug the charger must be grounde...

Страница 6: ...uched together Battery Connection Indicator If the charger does not detect a properly connected battery the CONNECTED red LED will not light Charging will not begin if the CONNECTED red LED is not on...

Страница 7: ...Limit If no button is pressed within 15 minutes after the battery charger is first powered up the charger will automatically switch from tester to charger if a battery is connected In that case the c...

Страница 8: ...may also be faulty This will happen if the battery did not reach full charge within 48 hours May be due to a very large battery or a bank of batteries requiring more power than the charger can deliver...

Страница 9: ...er is equipped with an auto start feature It will not supply current to the battery clips until a battery is properly connected Unlike traditional chargers the clips will not spark if touched together...

Страница 10: ...s no other warranties including but not limited to express implied or statutory warranties including without limitation any implied warranty of merchantability or implied warranty of fitness for a par...

Страница 11: ...a limitada expresa y el productor no autoriza ni otorga a alguien a realizar alguna otra obligaci n No existe ninguna otra garant a m s que la descrita en el manual del due o La tarjeta de garant a de...

Страница 12: ...12...

Страница 13: ...ga el cargador a la lluvia o a la nieve 1 3 Utilice solamente accesorios recomendados El uso de un accesorio no recomendado o suministrado por Schumacher Electric Corporation puede provocar riesgo de...

Страница 14: ...a para cargar bater as de pila seca que por lo general se utilizan con artefactos dom sticos Estas bater as podr an explotar y provocar lesiones a personas o da o a la propiedad 2 5 NUNCA cargue una b...

Страница 15: ...rma 5 PRECAUCIONES DE CONEXI N EN CC 5 1 Conecte y desconecte los ganchos de salida C C s lo despu s de haber desconectado el enchufe de C A del tomacorriente el ctrico 5 2 Sujete los ganchos a la bat...

Страница 16: ...e en posici n frontal a la bater a al realizar la conexi n final 7 6 Conecte el cond n de alimentaci n del cargador de CA al tomacorriente 7 7 Al desconectar el cargador siempre h galo en forma invers...

Страница 17: ...de auto marinas y de ciclo profundo No recomendable para uso industrial 10A 12A 15A Proporci n de Carga grande Para bater as de auto marinas y de tipo marino No se destina para las aplicaciones indus...

Страница 18: ...podr a llevar hasta 8 horas Si la desulfataci n no tiene xito se anular la carga Vea la secci n de Carga Anulada Finalizaci n de carga La finalizaci n de la carga se indica por medio del LED CARGADO...

Страница 19: ...hasta que el LED del ndice de carga se apague 12 INSTRUCCIONES DE MANTENIMIENTO 12 1 Despu s de usar y antes de realizar mantenimiento desenchufe y desconecte el cargador de la bater a ver secciones...

Страница 20: ...plena carga dentro de 36 horas Puede ser a causa de una bater a muy grande o banco de bater as que requiere m s fuerza de lo que el cargador puede proveer en 36 horas Reponga el corcel quitandolo Esc...

Страница 21: ...r Y corrija todas las conexiones El cargador no enciende a n cuando hay buena conexi n El tomacorriente est muerto Mala conexi n el ctrica Revise los fusibles del interruptor de circuitos que alimente...

Страница 22: ...o y da ino para una bater a tratar de forzar dentro de ella un amperaje mayor de lo que puede usar eficazmente en la recarga 15 3 Cuando se presenta un PROBLEMA DE OPERACI N DESCONOCIDO s rvase leer e...

Страница 23: ...das a t tulo enunciativo las garant as expresas impl citas o legales incluidas a modo de ejemplo las garant as impl citas de comerciabilidad o adecuaci n a un fin espec fico Asimismo el Fabricante no...

Отзывы: