4.9   Troubleshooting

                                                                   Version 11.01

18

Problem

Cause

Debugging

Main fuse 12 A is defect

Replace main fuse 12 a

The main switchs glows, but

If the main fuse is okey, check if the diode in the power supply

Replace fuse 1,6A in the power supply

the display isn't

is glowing. If not the fuse or the power supply is defect

or replace the power supply

the heating plate isn't heating up

If the diode is glowing

Replace the electronic devices

the electronic devices are defect

The display shows ”Err.5”

Thermal fuse on the heating plate is defect

Replace the thermal fuse

If you use the heating plate 400x500mm replace

both thermal fuses

The display shows ”Err.1”

Thermo couple is defect or the cables to the 

Check the cables to the thermo couple

thermo couple are defect

or exchange the thermo couple

No connection to the heating plate

Put the plug of the heating plat into the socket

The display shows ”Err.2”

The thermo couple is defect

Exchange the thermo couple

The display shows ”Err.3”

Resistance of the thermo couple is too low

Exchange the thermo couple

The display shows ”Err.4”

Resistance of the thermo couple is too high

The display shows ”Err.6”

Power relay CRYDOM is defect

Replace power relay CRYDOM

The display shows ”Err.7”

Adjustment buttons aren't working

Adjustment buttuns are defect

Replace adjusment buttons

No time or temperature adjustments are possible

Temperature of the heating plate doesn't correspond to the 

Malfunction of the electronic devices

Reset the electronic devices, but

Temperature on the display – Temperature too high/low

first contact Walter Schulze GmbH

The press heats up very slowly – over 30 minutes

One of the tow heating elements is defect

Replace the heating plate and/or send it in for repairs

one half of the plate doesn't reach the adjusted temperature

The press will not stay down

Micro switch is defect

Mikroschalter einstellen oder Mikroschalter austauschen

The time is not activated

The Material is to thick and so the micro switch isn't activated

The press will not close

Emergency button is pressed down

Pull the emergency button out

Compressed air is not connected

Connect the compressed air

The press will not open

Pneumatic valve is defect

Replace the pneumatic valve

Содержание BLUEpress

Страница 1: ...Instruction manual Version 11 01 Pneumatic press BLUEpress Version 11 01 1...

Страница 2: ...s 10 3 4 Application range and sample adjustments of the heat press 11 3 5 Pressure settings 11 3 6 Exchanging and rotating the heating plate 12 3 7 Exchanging and rotating the base plate 13 4 Mainten...

Страница 3: ...te 5 Contact pressure adjustment 6 Spiral tube 7 Heating plate 8 Base plate with silicon rubber 9 Extractable handles 10 Chassis 11 Handle to pull out the base plate 12 Fixation screw of the heating p...

Страница 4: ...lter with water separator 1 4 Technical data Dimensions of the press 750 x 500 x 850 mm Working plate 40 x 50 cm Weight 80 kg Operating voltage 230 VAC Rated power 40 x 50 cm 2 3 kW Air requirement pe...

Страница 5: ...lacing the main fuse can be found in chapter 4 3 Fuse 1 6A This fuse is placed in the 12VAC power supply in the upper part of the heat press It saves the 12VAC circuit of an overcharge Once the fuse w...

Страница 6: ...formed of the dangers of working with the press The details have to be explained in a coherent form and language Safety distance and ventilation The press has to be installed at a place which gives en...

Страница 7: ...ner you need to switch off the press at once and repair the compressor Oil in the system may be damage the press 2 4 Power supply Die BLUEpress has to be connected to a voltage of 230VAC 50Hz The pres...

Страница 8: ...3 Working with the heat press 3 1 Programming of electronic devices Version 11 01 8...

Страница 9: ...fter switching on the counter it counts the number of pressing activities a To end the programming of the electronic devices press button 1 b to get to the advanced programming menu press button 1 for...

Страница 10: ...r cancel it with button 3 3 3 Error reports The electronic devices of the BLUEpress control the main functions of the press Here is a list of possible messages ERR 1 No connection of the electronic de...

Страница 11: ...ettings Damages which arise from to much pressure are excluded from the guarantee To adjust the pressure do the following 1 Take the pressure reading 2 To alter the pressure pull the knop to you photo...

Страница 12: ...soft underground because the Teflon cover should not be damaged Then take the new heating plate and tighten it with the wrench Connect the heating plate with the press Turning the heating plate about...

Страница 13: ...of the base plate After exchanging the base plate you have to tighten the fixation screws again the pointed sides have to face up Rotating the base plate about 90 If you want to simplify the loading c...

Страница 14: ...Detailed instructions can be found in chapter 2 3 4 2 Monthly Maintenance Before beginning maintenance work control if the press is turned off and cold Disconnect the press from electricity Some mova...

Страница 15: ...ipped with a main fuse 1 6A 12Volt which is placed in the upper part of the press In the power supply there is a LED which can be controlled through the little holes in the upper part of the press pho...

Страница 16: ...ss Then reassemble the press again 4 6 Replacing the silicon mat To exchange the silicon mat the press must be disconnected from the electricity and cold For the exchange you need a new silicon mat si...

Страница 17: ...te 400 x 500 mm the same should be done with the second thermal fuse photo 4 4 8 Replacing the thermo couple The replacing may only be done by an authorized person For the replacement of the thermo co...

Страница 18: ...couple is too low Exchange the thermo couple The displayshows Err 4 Resistance of thethermo couple is too high The displayshows Err 6 Power relayCRYDOM is defect Replace power relayCRYDOM The display...

Страница 19: ...4 10 Connection diagram Version 11 01 19...

Страница 20: ...4 11 Controlling of the pneumatics Version 11 01 20...

Страница 21: ...on after EC guideline for machines 89 37 EC The Walter Schulze GmbH Schmalenbachstra e 15 12057 Berlin as European representative of the manufacturer company ROMANIK hereby declares that the following...

Страница 22: ...5 Spare parts and illustrations 5 1 Illustration 1 Pneumatics Version 11 01 22...

Страница 23: ...5 2 Illustration 2 The heat press Version 11 01 23...

Страница 24: ...5 3 Illustration 3 The heat press Version 11 01 24...

Страница 25: ...0 6bar 56 022 Tube 6 PA 126x4 BLA 56 023 Rubber foot 30x15 pcs 4 56 024 Pressure controller PX17102BD 56 025 Two hand control device 56 026 Bearing bush 56 027 Screw M10x30 pcs 4 56 028 Drawer 56 029...

Страница 26: ...Sws 6m 10 Screw M4x10 Heating plate Electronic devices ROM 5 Main switch C1553VB Fuse bracket Gewindemutter M5 pcs 4 Switch START STOP green ST22 Screw M3x15 Spiral tube Micro switch cover Micro switc...

Страница 27: ...screw M10x40 56 108 ball bearing 6000 ZZ 56 109 Aluminium part 20x20x73 56 110 Connection piece 5180 1 4 56 111 Connection piece 6463 6 1 8 56 112 Allen screw M6x15 pcs 2 56 113 Grommet 6 56 114 Alle...

Отзывы: