5.2 Installation
•
Fully insert the plug of the connecting cable into the socket on the underside of the lock.
•
Introduce the lock at an angle from above into the lock recess, in doing so feed the cable into the profile
(see fig. 7).
•
Be careful not to bend or strain the cable. Do not pull the cable taut!
•
Attach the lock at the designated fixing points on the profile using the two countersunk head screws
provided. If other screws are used, be careful
not
to exceed the maximum screw length of 18 mm as
otherwise the screws will strike against the lock case.
•
To complete the installation, put the lock in standby mode by sending a signal to the signal input.
max.
18 mm
270
120
24
24
16
154.5
Fig. 7: installation