S.B 1956; S.B 1959
10000429979-09.2016-02 | 15
Schüco International KG · Karolinenstraße 1–15 · D33609 Bielefeld
Function output e:
The function output displays the the following status reports:
•
The relay contact opens after the trigger lever has been actuated four times, while the door contact is
open, or if no jumper is installed at + 24 V:
•
The relay contact remains open following a voltage drop until authorised electrical access has been given
(control signal):
Signalling
In addition to the function indications at the relay outputs, the motor lock provides
status reports via a red LED in the lower area of the latchbolt hole.
These status reports provide information on the following incorrect operations:
• Actuation of profile cylinder when the motor is running
• Overload display, e.g. latchbolt difficult to move
The display of the LED can be switched off by retracting the latchbolt completely from
the locking position three times.
To delete the status report of a jammed latchbolt during daytime release, this must
also be accompanied by a successful actuation of the lock by the motor!
It is only possible to know for sure whether a "Door closed and locked" status
exists by connecting a door contact and this is therefore recommended.
NOTE
4x
PK
1
GY
2
VT
5
BK
6
YE
10
Door contact
+ 24
U
V DC
t
s
PK
11
GY
12
PK
11
GY
12
PK
11
GY
12
RD
13
GN
9
Fig.1: LED