GB
18
Connecting the motor
For the HLIS 997 model
!
The assembly comes is not equipped with a motor
and therefore must be connected to one (sold
separately) outside of the appliance itself. The
electrical connection must be made using the
appropriate terminals.
!
Only use 4-speed Scholtès motor.
Connecting the exhaust duct to the external motor
The external motor unit must be installed in a suitable
location in compliance with current safety regulations.
The motor and the assembly must be connected using
an exhaust duct with the correct diameter (Ø 150 mm).
To ensure that the hood operates efficiently, keep in
mind that ventilation becomes less efficient the longer
the exhaust duct which connects the assembly to the
motor. The exhaust duct must not exceed 7 meters in
length. The materials (the duct and the clamp) must
be provided by the installer.
Electrical connection for external motor
•
Check the position of electrical connection
compartment
B
situated over the hood.
•
Remove the screws to open the
B
compartment
cover.
•
Open the cable block by removing the
L
screws.
•
To connect the hood to the motor use a harmonized
omnipolar interconnection cable (HAR) type H05
VV-F (6 x 0,75mm
2
).
•
Connect the terminals of the cable coming from the
motor to the terminal board situated on the
B
compartment on the hood.
•
Close cable block
L
again (this should act to block
both the cable coming from the hood and the
electric connecting cable of the external motor).
•
Close cover
B
.
•
Carry out the electrical connection of the hood to
the power.
Fig. 9
Duct
External Motor Unit
harmonized omnipolar
interconnection cable (HAR)
type H05 VV-F (6 x 0,75mm
2
).
blue
white
red
grey
black
yellow/green
blue
white
red
grey
black
yellow/green