Страница 1: ...Spirit Wall Chimn ey Hood Instruction Manual SP612 SP912 Contact Caple on 0117 938 7420 for spare parts or www caple co uk ...

Страница 2: ...eep this instruction manual for future reference Introduction 3 Safety instructions 4 Environmental protection 9 Installation 10 Operation 16 Care and maintenance 17 Troubleshooting 18 Product Dimensions 19 Caple Contact Details 20 C ONTE NT S ...

Страница 3: ... appliance or visit www caple co uk and register here This instruction manual is designed to provide you with all the required information related to the installation use and maintenance of the appliance This hood is designed to extract unpleasant odours from the kitchen it is not intended to extract steam In order to operate the unit correctly and safely please read this instruction manual carefu...

Страница 4: ...esult in fire electric shock or injury To protect against fire electrical shock and injury to persons do not immerse cords or plugs in water or any other liquid Never touch the appliance with wet or damp hands Never pull the power cable as you could damage it If the appliance is faulty do not attempt to repair it Isolate it from the mains electric supply and contact Caple Service either by phone 0...

Страница 5: ...ever let children operate the machine The cooker hood is for home use only not suitable for barbecuing restaurants or other commercial purposes The cooker hood and its filter should be cleaned regularly in order to keep in good working condition Clean the cooker hood according to the instruction manual to reduce the risk of fire When using a gas hob do not leave naked flames under the extractor Be...

Страница 6: ...e air in the kitchen is being circulated before cooking commences and the air is being cleaned after cooking has finished The performance of your extractor will vary depending on a number of factors These include type of extraction room volume length of ducting ventilation available and the cleanliness of the filters This appliance is not intended for use by persons including children with reduced...

Страница 7: ...pe environments Bed and breakfast type environments To avoid all risk if the power cable is damaged it must only be replaced by a Caple appointed engineer Appliances can be used by persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazard...

Страница 8: ...ice from a suitably qualified engineer Failure to follow these instructions can result in death fire or electrical shock This appliance must be connected to the mains by a competent person We recommend that the appliance is connected by a qualified electrician who is a member of the N I C E I C who will comply with the I E E and local regulations Electrical information can be found on the rating p...

Страница 9: ...your local council your household waste disposal service or the retailer where you purchased the product WARRANTY Your new appliance is covered by warranty The warranty card is enclosed if it is missing you must provide the following information to your retailer in order to receive a replacement date of purchase model and serial number Registration can also be completed online by visiting www capl...

Страница 10: ...e outlet The cooker hood should be installed so that there is a space of 650 760mm from the centre of the mesh grease filters to the hob 435 545mm from the bottom of the hood to the hob It is the manufacturer of the hob who determines the clearance required and the clearance quoted by the hob manufacturer must be followed In the absence of any instructions supplied with a gas hob the minimum dista...

Страница 11: ...od and appliance supplied with energy other than electricity are simultaneously in operation the negative pressure in the room must not exceed 4 Pa 4 10 5 Bar Drill 3 x 8mm holes to accommodate the bracket Screw and tighten the bracket onto the wall with the screws and screw plugs provided Level up the cooker hood and hang onto the wall bracket hook Holes on wall Screw Plug Wall Bracket Screw 4mm ...

Страница 12: ...pen the front panel and remove the grease filters mark 2 holes inside the hood for safety screws After marking remove the hood drill two holes and insert 2 wall plugs Hang the hood back onto the wall and finally fix the safety screws with 2 screws ST4x30mm Place the plastic duct on the cooker hood outlet Installation Installation ...

Страница 13: ...decide the upper chimney bracket fixing holes for installation Screw 4mm x 8mm Screw 4mm x 30mm Wall Plug Upper Chimney Bracket The lower chimney bracket is used to fix the upper decorative chimney and lower decorative chimney Use 2pcs 4x8mm screws to attach lower chimney and lower chimney bracket together Put the lower chimney on the cooker hood and mark the location of lower chimney bracket fixi...

Страница 14: ...you do not have an outlet to the outside the exhaust pipe is not required as shown in the section Installation ducted and charcoal filters must be installed ACCESSING THE GREASE FILTER To access the grease filter pull the bottom slat from the base upwards and it will lift up as shown below 8 and must be installed ...

Страница 15: ... the charcoal filter the grease filter should be detached first Press the release button and pull it downward as shown below Fit the activated charcoal filter onto the side of the motor and turn it in a clockwise direction to lock into place Repeat the same on the other side Scan the QR Code to access the How To video NOTE Make sure the filter is securely locked Otherwise it may loosen and be dang...

Страница 16: ...low Press again to switch off LOW SPEED BUTTON Is suitable for simmering and cooking which does not produce much steam or odour MEDIUM SPEED BUTTON Airflow speed is ideal for extracting with standard cooking HIGH SPEED BUTTON When a high amount of steam or odours are produced use the high speed setting for the most effective extraction LIGHT BUTTON Switches the light on and off OP ER AT ION TOUCH ...

Страница 17: ...up liquid alternatively the filters can be cleaned in your dishwasher Please ensure no other items are washed with the filters they must be washed separately to prevent food becoming trapped in the gauze Cleaning the grease filters in the dishwasher may lead to discolouration this is normal and is a not a fault with the product REPLACING YOUR CHARCOAL FILTER This only applies if you are using the ...

Страница 18: ...amaged Switch off the unit and contact Caple Service To be repaired by qualified service personnel only The fan motor is not fixed tightly Switch off the unit and contact Caple Service To be repaired by qualified service personnel only The unit is not hung correctly on the bracket Take down the unit and check whether the bracket is in the correct location The extraction performance is not good The...

Страница 19: ...SP612 SP912 D I M E N S I O N S 280mm 320mm 500 980mm 5 0 0 m m 500mm 595 895mm 650mm space for electric hobs and 760mm space for gas hobs required from worktop to the mesh filter behind the centre glass panel From the lowest point of the hood the distance required is 450mm for electric hobs and 550mm for gas hobs ...

Страница 20: ...Caple Service Fourth Way Avonmouth Bristol BS11 8DW T 0117 938 1900 E service caple co uk www caple co uk ...