background image

1

WARNING  

 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufac-

turer. If you have questions, contact the manufacturer at
the address or telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at ser-

vice panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.

3. Installation work and electrical wiring must be done by a

qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.

4. Sufficient air is needed for proper combustion and exhaust-

ing of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
thorities.

5. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any solid-state speed control de-

vice.

8. To reduce the risk of fire, use only metal ductwork.
9. Use with approved cord-connection kit only.
10. This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

1. Never leave surface units unattended at high settings.

Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.

2. Always turn hood ON when cooking at high heat or when

cooking flaming foods.

3. Clean ventilation fans frequently. Grease should not be al-

lowed to accumulate on fan or filter.

4. Use proper pan size. Always use cookware appropriate for

the size of the surface element.

IMPORTANT

For Non-ducted (Ductfree) Installation:

a) Purchase non-ducted filter separately.
b) Remove and discard damper/duct connector and louver cover

(See Step 4) in “Prepare the Hood,” Page 2.

c) Follow all steps except steps inside dotted lines.

For Ducted Installation:

Follow all steps, including steps inside dotted lines.

F30WC, F36WC, & F42WC SERIES
4-WAY CONVERTIBLE RANGE HOOD

READ AND SAVE THESE INSTRUCTIONS

!

 INTENDED FOR DOMESTIC COOKING ONLY 

!

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:*

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or

metal tray, then turn off the burner. BE CAREFUL TO PRE-
VENT BURNS. If the flames do not go out immediately, EVACU-
ATE  AND CALL THE FIRE DEPARTMENT.

2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels -

a violent steam explosion will result.

4. Use an extinguisher ONLY if:

A. You know you have a Class ABC extinguisher and you

already know how to operate it.

B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.

CAUTION  

!

1. For general ventilating use only. Do not use to exhaust

hazardous or explosive materials and vapors.

2. To avoid motor bearing damage and noisy and/

or unbalanced impellers, keep drywall spray,
construction dust, etc. off power unit.

3. Your hood motor has a thermal overload which will automatically

shut off the motor if it becomes overheated. The motor will
restart when it cools down. If the motor continues to shut off
and restart, have the hood serviced.

4. For best capture of cooking impurities, your range hood should

be mounted 18-24" above the cooking surface.

5. Please read specification label on product for further information

and requirements.

WARNING  

 

INSTALLER:  Leave This Manual With

the Homeowner.

HOMEOWNER:  Use and Care

Information on Page 5.

Содержание F30WC Series

Страница 1: ...ed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element IMPORTANT For Non ducted Ductfree Installation a Purchase non ducted filter separately b Remove and discard damper duct connector and louver cover See Step 4 in Prepare the Hood Page 2 c Follow all steps except steps inside dotted lines For Ducted Installation Follow all step...

Страница 2: ...ations a 3 1 4 rectangular ducting range hood can be converted to a round duct by means of a transition FIG 1A Ducting directly through the wall for range hoods mounted on an exterior wall Shown are two ways to duct through an outside wall If a wall cap is used directly off the back of the hood special care must be taken to make sure that the damper in the damper duct connector on the hood and dam...

Страница 3: ...above hood Seal joint between damper duct connector and hood with duct tape 8 7 round ducted discharge only Re install 7 round duct plate removed in Step 2 under PREPARING THE RANGE HOOD section For best performance line up the 7 round duct plate with the 7 round opening on hood Mount duct plate to hood with 2 screws from duct plate and 2 screws from 3 x 10 damper Install a 7 round damper purchase...

Страница 4: ...om so that the duct will overlap the damper duct connector by 3 4 when the hood is installed ROOF CAPS Cut hole in roof slightly larger than duct so duct will line up easily with hood Trim shingles around hole so that they will fit snugly around hood of cap when cap is installed Assemble the duct work and tape all joints Run the duct work down to hood Trim duct parallel to roof pitch leaving 3 4 o...

Страница 5: ...place wiring box cover and screw Make sure that all wir ing is safely contained inside NOTE For Ductfree Installations Only Install both filters Make sure that ductfree filter purchase separately is next to fan assembly with blue side next to blade Aluminum filter should be facing out FILTER REMOVAL Filters are removed by turning filter clip to the side and lifting filter or filters out In ducted ...

Страница 6: ...rately 11 Filter Retainer 12 8B x 1 4 Hex Head Sheet Metal Screws 2 Req 13 Damper Flap 14 Damper Bushing 15 Damper Assembly Includes Key Nos 13 and 14 16 Nameplate Black Nameplate White Nameplate Biscuit 17 2 Speed Motor Switch Black 2 Speed Motor Switch White 2 Speed Motor Switch Biscuit 18 Light Switch Black Light Switch White Light Switch Biscuit 19 Motor Receptacle with Wires 20 Louver Cover B...

Страница 7: ...7 ...

Страница 8: ...RCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW BUT NOT LESS THAN ONE YEAR ELECTROLUX SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIM...

Отзывы: