Instructions for Use
– SCHMIDT
®
LED Measured Value Display MD 10.010
Page 10
Auxiliary display
State
Alarm output 1: Not activated
Alarm output 2: Not activated
Alarm output 1: Activated
Alarm output 2: Not activated
Alarm output 1: Not activated
Alarm output 2: Activated
Alarm output 1: Activated
Alarm output 2: Activated
Table 3 Alarm indication
Handling
The device can be operated by means of two different menus which are
activated from standard mode using the parameter key
:
Shortly press the parameter key to open the display menu.
In this menu, the actual measured values
of “Sensor 1”, the stored
peak values (minimum and maximum) of the standard value as well as
the switching points of the alarm outputs can be sequentially displayed
by further pressing of the parameter key.
If the key is
n’t pressed for more than 2 minutes, the device returns
automatically to standard mode.
If the parameter key is pressed for more than 2 seconds, the configu-
ration menu opens.
It can be used to configure the measuring input (sensor signal), both
alarm outputs and the analog output (details see chapter
).
The menu items are selected sequentially by using the parameter key
(short press). The settings of the currently selected menu item can be
modified using the arrow keys (
).
The configuration menu is closed after the last menu item or, if no key
is pressed for more than two minutes, it is exited automatically. It can
also be quitted at any time by pressing the parameter key for a longer
time (more than 2 seconds).
Table 4 shows an overview of the presentation and meaning of the differ-
ent menu items in the auxiliary display.