The tension meter features a data logger with a memory capacity for up to 4000 readings,
with which you can store different measuring periods at one or more machine positions.
The readings are saved 2x per sec-
ond, synchronously with the display
update rate, in all memory modes
except the “F” mode in which they
are saved 100x per second. All saved
readings and statistics can be shown
on the display or transmitted to a PC
(e.g. for further processing in Excel).
The memory can be allocated to dif-
ferent measuring periods, depending
on the memory mode.
3.5 Memory Modes
Memory Mode
S
C
L
F
Meas. periods,
max.
255
255
255
255
Readings, max.
-
4000
4000
4000
Max. no. of read-
ings per position
-
Any
10
Any
Statistics
Yes
Yes
Yes
Yes
Save readings
-
Yes
Yes
Yes
The selected memory mode remains stored in the KXE memory even after the in-
strument is switched off.
Memory mode “S”
STANDARD
(default):
The following values of a measuring
period are calculated and saved at a
rate of 2 readings per second:
Average value,
Last value,
Maximum value
(MAX),
Minimum value
(MIN),
Minimum peak value
(MIN PEAK)
Maximum peak value
(MAX PEAK)
Individual readings are not saved.
You can save up to 255 measuring
periods.
Memory mode “C”
CONTINUOUS:
The following values of a measuring
period are calculated and all readings are
additionally saved at a rate of 2 readings
per second:
Average value,
Last value,
Maximum value
(MAX),
Minimum value
(MIN),
Minimum peak value
(MIN PEAK)
Maximum peak value
(MAX PEAK)
You can save up to 4000 readings, split
up into up to 255 measuring periods.
Memory mode “L”
LIMIT:
The following values of a measuring period
are calculated and 10 readings are addition-
ally saved at a rate of 2 readings per second:
Average value,
Last value,
Maximum value
(MAX),
Minimum value
(MIN),
Minimum peak value
(MIN PEAK)
Maximum peak value
(MAX PEAK)
You can save up to 255 measuring periods
with 10 readings each.
Memory mode “F”
FAST:
The following values of a measuring period
are calculated and all readings are additional-
ly saved at a rate of 100 readings per second:
Average value,
Last value,
Maximum value
(MAX),
Minimum value
(MIN),
Minimum peak value
(MIN PEAK)
Maximum peak value
(MAX PEAK)
You can save up to 4000 readings, split up
into up to 255 measuring periods.