schmersal CSS 34 Скачать руководство пользователя страница 1

CSS 34

Operating instructions

Safety relay module

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional  

information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 

Target group: authorised qualified personnel

. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Comprehensive quality insurance to 2006/42/EC  . . . . . . . . . . . . . .2

2.4  Purpose  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.6 

Safety classification

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.3  Actuating positions of the safety sensor with regard to the actuator 4

3.4  Switch distance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.5  Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .5

4.2  Series-wiring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

5  Diagnostic functions

5.1  Operating principle of the diagnostic LEDs  . . . . . . . . . . . . . . . . . . .6

5.2  Operating principle of the electronic diagnostic output  . . . . . . . . . .6

5.3  Safety-sensors with serial diagnostic function . . . . . . . . . . . . . . . . .7

6  Set-up and maintenance

6.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

6.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

7  Disassembly and disposal

7.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

7.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

8  Appendix

8.1  Wiring examples  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

8.2 

Wiring configuration and connector accessories

. . . . . . . . . . . . . . .9

9  EU Declaration of conformity

x.000 / 01.2020 / v

.A.   -   101

185245-EN / I / 2020-01-10 / 

AE-Nr

. 1

1847

EN

Operating instructions. . . . . . . . . . . .pages 1 to 10

Original

Содержание CSS 34

Страница 1: ...he safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applicatio...

Страница 2: ...the position of movable safety guards In this application the safety sensor monitors the position of hinged sliding or removable safety guards by means of the coded electronic CST 34 or CST 180 actuat...

Страница 3: ...ISO 13849 1 IEC 61508 IEC 62061 PL e Control Category 4 PFH value 3 6 x 10 9 h SIL suitable for SIL 3 applications Mission time 20 years 3 Mounting 3 1 General mounting instructions Please observe the...

Страница 4: ...34 V 1 CSS 34 V CST 34 S 3 CSS 34 S CSS 34 V CST 34 S 3 CST 34 S 2 CSS 34 S CSS 34 V CST 34 S 2 CST 180 1 2 CSS 34 S CSS 34 V CST 180 1 2 3 4 Switch distance Actuators and switching distances to EN 60...

Страница 5: ...y channel must be observed Contactors with higher load currents must be controlled by intermediate control relays Information for the selection of suitable safety monitoring modules can be found in th...

Страница 6: ...he distance to the actuator increases and before the safety outputs are disabled thus stopping the machine IV Error warning sensor actuated On Flashes On 0 V 24 V After 30 minutes if the error is not...

Страница 7: ...e request byte changes from 1 to 0 or the safety guard is opened Faults at the safety outputs are only deleted upon the next release as the fault rectification cannot be detected sooner For devices wi...

Страница 8: ...2 3 5 4 6 8 X1 Y1 X2 7 Y2 7 Y2 SD IN SD OUT A1 A2 X1 Y1 X2 Y2 SD IN SD OUT Y1 Y2 SD IN 24 VDC GND CST 34 S 1 CSS 34 CST 34 S 1 CSS 34 Safety outputs Evaluation Gateway 6 Set up and maintenance 6 1 Fu...

Страница 9: ...PVC to IEC 60947 5 2 2007 A1 Ue 1 WH BN BN X1 Safety input 1 2 BN WH WH A2 GND 3 GN BU BU Y1 Safety output 1 4 YE BK BK OUT Diagnostic output SD output 5 GY GY GY X2 Safety input 2 6 PK VT PK Y2 Safe...

Страница 10: ...006 42 EC 2014 30 EU 2011 65 EU Machinery Directive EMC Directive RoHS Directive Applied standards EN 60947 5 3 2013 ISO 14119 2013 EN ISO 13849 1 2015 EN 61508 parts 1 7 2010 EN 62061 2005 AC 2010 A1...