schmersal CSS 34 Скачать руководство пользователя страница 2

2

Operating instructions

Safety sensor

CSS 34

EN

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

1.6  Warning about misuse

In case of improper use or manipulation of the safety 

switchgear, personal hazards or damages to machinery 

or plant components cannot be excluded. The relevant 

requirements of the standard ISO 14119 must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

CSS-

-34

-

-M-

No.

Option

Description

12

14

Switching distance S

n

 (mm)

Actuation from top

Actuation from side

S

lateral active surface

V

frontal active surface

D

With diagnostic output

SD

With serial diagnostic function

L

with connecting cable

ST

with integrated connector

Only if the information described in this operating instructions 

manual are realised correctly, the safety function and 

therefore the compliance with the Machinery Directive is 

maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond to 

the standard version.

2.3  Comprehensive quality insurance to 2006/42/EC

Schmersal is a certified company to appendix X of the Machinery 

Directive. As a result, Schmersal is entitled to autonomously conduct 

the conformity assessment procedure for the products listed in 

Appendix IV of the MD without involving a notified body. The prototype 

test certificates are available upon request or can be downloaded from 

the Internet at www.schmersal.com.

2.4  Purpose

This non-contact, electronic safety sensor is designed for application in 

safety circuits and is used for monitoring the position of movable safety 

guards. In this application, the safety sensor monitors the position of 

hinged, sliding or removable safety guards by means of the coded 

electronic CST 34 or CST 180 actuators (refer to table "Actuators and 

switching distances").

The safety function consists of safely switching off the safety outputs 

when the safety guard is opened and maintaining the safe switched off 

condition of the safety outputs for as long as the safety guard is open.

The safety switchgears are classified according to 

ISO 14119 as type 4 switching devices.

The diagnostic output of the CSS 34 safety sensor alternatively can be 

used as conventional output or as “serial output“ with input and output 

channel. 

Series-wiring

Series-wiring can be set up. Response and risk times remain 

unchanged by series-wiring. The number of components is only limited 

by the external cable protection according to the technical data and 

the line loss. Series-wiring of up to 31 CSS 34 … SD components with 

serial diagnostics is possible.In devices with the serial diagnostics 

function (ordering suffix -SD), the serial diagnostics connections 

are wired in series and connected to a SD Gateway for evaluation 

purposes.

Wiring examples for series-wiring, refer to appendix.

The user must evaluate and design the safety chain in 

accordance with the relevant standards and the required 

safety level.

If multiple safety sensors are involved in the same safety 

function, the PFH values of the individual components must 

be added.

The entire concept of the control system, in which the safety 

component is integrated, must be validated to the relevant 

standards.

2.5  Technical data

Standards:

  

IEC 60947-5-3, ISO 13849-1,  

IEC 61508, IEC 62061

Enclosure:

 

glass-fibre reinforced thermoplastic

Operating principle:

 inductive

Coding level according to ISO 14119:

 low

Actuator and switch distances  

(according to IEC 60947-5-3):

  see table "Actuator / Switch distances“

Hysteresis:

 

max: 1.5 mm

Repeat accuracy R:

 

< 0.5 mm

Maximum switching frequency:

 

3 Hz

Series-wiring:

 

Unlimited number of components,  

please observe external cable protection,  

max. 31 components in case of serial diagnostics

Cable length:

 

max. 200 m (cable length and cable section alter the 

voltage drop depending on the output current)

Connector:

 

M12, 8-pin in casing

Pre-wired cable:

 

Y-UL 2517 / 8 × AWG 22 / 8 × 0.35 mm², 2 m

Temperature resistance of the cable: 

 

- at rest:

 

−30 °C … +105 °C

 

- in motion:

 

−10 °C … +105 °C

Ambient conditions: 

Ambient temperature T

u

:

 

–25 °C to +70 °C 

 

with output current ≤ 0.1 A / Output

 

–25 °to +65 °C 

 

with output current ≤ 0.25 A / Output

Storage and transport temperature:

 

–25 °C … +85 ºC

Resistance to vibration:

 

10 … 55 Hz, amplitude 1 mm

Resistance to shock:

 

30 g / 11 ms

Protection class:

 

IP65, IP67 to IEC 60529

Содержание CSS 34

Страница 1: ...he safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applicatio...

Страница 2: ...the position of movable safety guards In this application the safety sensor monitors the position of hinged sliding or removable safety guards by means of the coded electronic CST 34 or CST 180 actuat...

Страница 3: ...ISO 13849 1 IEC 61508 IEC 62061 PL e Control Category 4 PFH value 3 6 x 10 9 h SIL suitable for SIL 3 applications Mission time 20 years 3 Mounting 3 1 General mounting instructions Please observe the...

Страница 4: ...34 V 1 CSS 34 V CST 34 S 3 CSS 34 S CSS 34 V CST 34 S 3 CST 34 S 2 CSS 34 S CSS 34 V CST 34 S 2 CST 180 1 2 CSS 34 S CSS 34 V CST 180 1 2 3 4 Switch distance Actuators and switching distances to EN 60...

Страница 5: ...y channel must be observed Contactors with higher load currents must be controlled by intermediate control relays Information for the selection of suitable safety monitoring modules can be found in th...

Страница 6: ...he distance to the actuator increases and before the safety outputs are disabled thus stopping the machine IV Error warning sensor actuated On Flashes On 0 V 24 V After 30 minutes if the error is not...

Страница 7: ...e request byte changes from 1 to 0 or the safety guard is opened Faults at the safety outputs are only deleted upon the next release as the fault rectification cannot be detected sooner For devices wi...

Страница 8: ...2 3 5 4 6 8 X1 Y1 X2 7 Y2 7 Y2 SD IN SD OUT A1 A2 X1 Y1 X2 Y2 SD IN SD OUT Y1 Y2 SD IN 24 VDC GND CST 34 S 1 CSS 34 CST 34 S 1 CSS 34 Safety outputs Evaluation Gateway 6 Set up and maintenance 6 1 Fu...

Страница 9: ...PVC to IEC 60947 5 2 2007 A1 Ue 1 WH BN BN X1 Safety input 1 2 BN WH WH A2 GND 3 GN BU BU Y1 Safety output 1 4 YE BK BK OUT Diagnostic output SD output 5 GY GY GY X2 Safety input 2 6 PK VT PK Y2 Safe...

Страница 10: ...006 42 EC 2014 30 EU 2011 65 EU Machinery Directive EMC Directive RoHS Directive Applied standards EN 60947 5 3 2013 ISO 14119 2013 EN ISO 13849 1 2015 EN 61508 parts 1 7 2010 EN 62061 2005 AC 2010 A1...

Отзывы: