Nødvendig nominell kortslutningsstrøm iht EN 60947-5-1
100 A
External wire and device fuse rating
2 A gG
Brytefrekvens, maksimum
0,5 Hz
Elektriske data - Solenoidkontroll INN
Designation, Magnet control
IN
Koblingsterskeler for magnetinnganger
-3 V … 5 V (Low)
15 V … 30 V (High)
Driftsstrøm for solenoidkontroll ved 24 V
10 mA
Magnet switch-on time
100 %
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
40 ms
Classification ZVEI CB24I, Sink
C0
Classification ZVEI CB24I, Source
C1
C2
C3
Electrical data - Safety digital inputs
Designation, Safety inputs
X1 und X2
Koplingsterskler på sikkerhetsinnganger
−3 V … 5 V (Low)
15 V … 30 V (High)
Driftsstrøm for sikkerhetsinngangene ved 24 V
5 mA
Test pulse duration, maximum
1 ms
Test pulse interval, minimum
100 ms
Classification ZVEI CB24I, Sink
C1
Classification ZVEI CB24I, Source
C1
C2
C3
Electrical data - Safety digital outputs
Designation, Safety outputs
Y1 and Y2
Sikkerhetsutgang
short-circuit proof, p-type
Voltage drop U
d
, maximum
2 V
Leakage current I
r
, maximum
0,5 mA
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0,25 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0,25 A
Test pulse duration, maximum
0,5 ms
Test pulse interval, typical
1000 ms