For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the
device are strictly forbidden, the manufacturer shall accept no liability for damages resulting from such invasive
work, arbitrary repairs, conversions and/or modifications to the device.

2.6 Technical Data

Tillatelser - Standard

Data

TÜV
cULus
ECOLAB
EAC
FCC
IC

Gobale egenskaper

Standard

EN ISO 13849-1
EN ISO 14119
EN IEC 60947-5-3
EN IEC 61508

Generell informasjon

Universell koding

Coding level according to EN ISO 14119

lav

Aktivt prinsipp

RFID

Frequency band RFID

125 kHz

Transmitter output RFID, maximum

-6 dB/m

Kapslingsmateriale

Plast, glassfiber forsterket termoplast selvslukkende

Bruttovekt

610 g

Tid til beredskap , maksimum

5 000 ms

Farens varighet, maksimum

200 ms

Reaksjonstid for aktivatoren, maksimum

100 ms

Reaksjonstid for inngangene, maksimum

1,5 ms

Gobale egenskaper - Karakteristikker

Aktivator overvåket

Ja

Fast posisjon

Ja

Nødutgang

Ja

Kortslutningsdeteksjon

Ja

Kortslutningsgjenkjenning

Ja

Seriekabling

Ja

Sikkerhetsfunksjoner

Ja

Integrert indikator, status

Ja

Содержание AZM300B-ST-1P2P-A-T

Страница 1: ...cy release N 3 4 Mounting with mounting plate 3 5 Dimensions 3 6 Actuator and accessories 4 Electrical connection 4 1 General information for electrical connection 4 2 Serial diagnostic SD 4 3 Wiring examples for series wiring 4 4 Wiring configuration and connector accessories 5 Actuator coding and latching force adjustment 5 1 Actuator coding 5 2 Latching force adjustment 6 Active principle and d...

Страница 2: ... and is subject to technical modifications 1 3 Explanation of the symbols used F Information hint note This symbol is used for identifying useful additional information 2 Caution Failure to comply with this warning notice could lead to failures or malfunctions Warning Failure to comply with this warning notice could lead to physical injury and or damage to the machine 1 4 Appropriate use Products ...

Страница 3: ...en Standard koding I1 individuelt kodet I2 Individuelt kodet multippel innlæring 3 1P2P 1 diagnoseutgang p type og 2 sikkerhetsutganger p type SD2P Seriell diagnoseutgang og 2 sikkerhetsutganger p type 4 uten åpner med spenning A driftsspenning 5 uten Manuell tvangsåpning N Nødåpning T Nødutgang 2 2 Special versions For special versions which are not listed in the ordering code these specification...

Страница 4: ...set up In the case of a series connection the risk time remains unchanged and the reaction time increases by the sum of the reaction time of the inputs per additional unit specified in the technical data The quantity of devices is only limited by the cable drops and the external cable fuse protection according to the technical data Up to 31 device variants with serial diagnostics can be wired in s...

Страница 5: ... EN IEC 61508 Generell informasjon Universell koding Coding level according to EN ISO 14119 lav Aktivt prinsipp RFID Frequency band RFID 125 kHz Transmitter output RFID maximum 6 dB m Kapslingsmateriale Plast glassfiber forsterket termoplast selvslukkende Bruttovekt 610 g Tid til beredskap maksimum 5 000 ms Farens varighet maksimum 200 ms Reaksjonstid for aktivatoren maksimum 100 ms Reaksjonstid f...

Страница 6: ...jeningshastighet 0 5 m s Angular misalignment between solenoid interlock and actuator maximum 2 Klemmekraft iht EN ISO 14119 1 150 N Klemmekraft maksimum 1 500 N Latching force adjustable position 1 25 N Latching force adjustable position 2 50 N Type of the fixing screws 2x M6 Tightening torque of the fixing screws minimum 6 Nm Tightening torque of the fixing screws maximum 7 Nm Mechanical data Sw...

Страница 7: ...simum 90 C Relativ fuktighet maksimum 93 Note Relative humidity ikke kondenserende ikke ising Resistent mot vibrasjoner iht EN 60068 2 6 10 150 Hz Amplitude 0 35 mm sjokkresitanse 30 g 11 ms Protection class III Permissible installation altitude above sea level maximum 2 000 m Ambient conditions Insulation values Isolasjonsspenning 32 VDC Nominell impulsmotstandsspenning 0 8 kV Overvoltage categor...

Страница 8: ...s Designation Safety inputs X1 und X2 Koplingsterskler på sikkerhetsinnganger 3 V 5 V Low 15 V 30 V High Driftsstrøm for sikkerhetsinngangene ved 24 V 5 mA Test pulse duration maximum 1 ms Test pulse interval minimum 100 ms Classification ZVEI CB24I Sink C1 Classification ZVEI CB24I Source C1 C2 C3 Electrical data Safety digital outputs Designation Safety outputs Y1 and Y2 Sikkerhetsutgang short c...

Страница 9: ...PIN 3 A2 GND PIN 4 Y1 Sikkerhetsutgang 1 PIN 5 OUT DIagnostisk utgang PIN 6 X2 Sikkerhetsinngang 2 PIN 7 Y2 Sikkerhetsutgang 2 PIN 8 IN Solenoidkontroll Note about the safety classification 2 The safety consideration of the guard locking function only applies for standard devices with monitored solenoid interlock AZM300Z 1P2P see Ordering code A safety assessment of the guard locking function for ...

Страница 10: ...t must be supplied with at least 24 V DC and 0 8 A via a listed CYJV cable connector assembly FCC IC Note This device complies with Part 15 of the FCC Rules and contains licence exempt transmitter receivers that are compliant with ISED Innovation Science and Economic Development Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause ha...

Страница 11: ...uator Refer to the mounting instructions manual for the corresponding actuator 2 The actuator must be permanently fitted to the safety guards and protected against displacement by suitable measures tamperproof screws gluing drilling of the screw heads Actuating directions The diagrams show a closed guard system with a set latching force of 50 N see also chapter adjustment of latching force ...

Страница 12: ...d of system and any reduction of the switching distances please observe the following guidelines The presence of metal chips in the vicinity of the solenoid interlock is liable to modify the switching distance Keep away from metal chips Minimum distance between two solenoid interlocks as well as other systems with same frequency 125 kHz ...

Страница 13: ...can be unlocked in a de energised condition The solenoid interlock is unlocked by turning the manual release in the position qThe normal locking function is only restored after the manual release has been returned to its original position p Caution do not turn beyond the end stop Key A connector plug M12 8 pole B LED display C1 Manual release by means of slotted screwdriver ...

Страница 14: ...o the end stop The safety outputs switch off and the guard system can be opened The blocked position is cancelled by turning the lever in the opposite direction In the unlocked position the guard system is secured against unintentional locking 2 Emergency release N Fitting and actuation only from outside the hazardous area The emergency release should only be used in an emergency The solenoid inte...

Страница 15: ...t when the red lever is actuated the opposite lever also rotates As such the procedure outlined above must be followed to release the emergency release lever 3 4 Mounting with mounting plate For doors which close flush with the door frame the optional mounting late MP AZ AZM300 1 can be used 3 5 Dimensions All measurements in mm AZM300 T T8 and N Device with emergency exit or emergency release Eme...

Страница 16: ...Emergency exit T8 3 6 Actuator and accessories Actuator AZ AZM300 B1 not included in delivery Mounting plate MP AZ AZM300 1 available as accessory ...

Страница 17: ...MS AZ AZM300 B1 1 available as accessory Aluminium protective plate as a cover for use on glass and plastic doors on machines with high design requirements Lockout tag SZ 200 1 available as accessory ...

Страница 18: ...ection 2 The electrical connection may only be carried out by authorised personnel in a de energised condition The voltage inputs A1 X1 X2 and IN must have a protection against permanent overvoltage Supply units according to EN 60204 1 is recommended The required electrical cable fuse protection must be integrated in the installation The safety outputs can be integrated into the safety circuit of ...

Страница 19: ...ccessories for the series wiring For convenient wiring and series wiring of SD components the SD junction boxes PFB SD 4M12 SD variant for the field and PDM SD 4CC SD variant for control cabinet on carrier rail are available along with additional comprehensive accessories Detailed information is available on the Internet products schmersal com 4 3 Wiring examples for series wiring Series wiring ca...

Страница 20: ...e serial diagnostics connections are wired in series and connected to a SD Gateway for evaluation purposes The safety outputs of the first safety component are wired to the safety monitoring module The serial Diagnostic Gateway is connected to the serial diagnostic input of the first safety component Y1 and Y2 Safety outputs Safety monitoring module SD IN Gateway Field bus 4 4 Wiring configuration...

Страница 21: ...N Solenoid control SD input 8 RD PK OR Connecting cables with coupling female IP67 IP69 M12 8 pole 8 x 0 25 mm to DIN 47100 Cable length Ordering code 2 5 m 103011415 5 0 m 103007358 10 0 m 103007359 15 0 m 103011414 Connecting cables with coupling female IP69K M12 8 pole 8 x 0 21 mm Cable length Ordering code 5 0 m 101210560 5 0 m angled 101210561 10 0 m 103001389 15 0 m 103014823 5 Actuator codi...

Страница 22: ... of the time of the enabling inhibit and the detection of the new actuator In case of power failure during the lapse of time the 10 minutes tampering protection time will restart 5 2 Latching force adjustment In order to enable trouble free functionality of the device the rotary handle must be in position I or II when the safety guard is open In the intermediate positions locking is impossible The...

Страница 23: ... is not a safety related output Error Errors which no longer guarantee the function of the safety switchgear internal errors cause the safety outputs to be disabled within the duration of risk After fault rectification the error message is reset by opening and re closing the corresponding safety guard Fault warning A fault that does not immediately endanger the safety function of the safety switch...

Страница 24: ... guard closed Locking time Safety guard not locked or fault Safety guard locked Lock Unlock Evaluation of diagnostic output Power to unlock IN 0 Lock Safety guard can be locked Safety guard locked Power to lock IN 1 Lock Safety guard can be locked Safety guard locked ...

Страница 25: ...ashes 0 V 0 V 0 V Only I2 teach in procedure actuator release block Flashes Off On 0 V 0 V 0 V 1 after 30 min disabling due to fault 2 refer to flash code Table 2 Error messages flash codes red diagnostic LED Flash pulses red Designation Autonomous switch off after Error cause 1 flash pulse Error warning at output Y1 30 min Fault in output test or voltage at output Y1 although the output is disabl...

Страница 26: ... the PLC In case of a communication error between the SD gateway and the solenoid interlock the switching condition of the solenoid interlock is maintained Error Errors which no longer guarantee the function of the safety switchgear internal errors cause the safety outputs to be disabled within the duration of risk The fault is reset when the cause is eliminated and bit 7 of the request byte chang...

Страница 27: ...ed or when pulling the door The solenoid interlock can only be locked if the turret is in the rest position i e the latching force is sufficient to pull the guard system into the correct position 2 after 30 min fault 7 Set up and maintenance The safety function of the safety components must be tested In the case of correct installation and adequate use the safety switchgear features maintenance fr...

Страница 28: ...sassembly and disposal 8 1 Disassembly The safety switchgear must be disassembled in a de energised condition only 8 2 Disposal The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations ...

Отзывы: