Chapter 3 / 4 

Description / Installation

 

J. Schmalz GmbH 
Aacher Straße  29 
D  - 72293 Glatten 
Tel  +49 +7443 / 2403 - 0 
Fax +49 +7443 / 2403 - 259 
http://www.schmalz.de 
e-mail: [email protected] 

 

 

BA 30.30.01.00238 

Status 03.2013 / Index 00 

Page 9 / 16 

3.5  Suction Pads 

 

Danger

 

Danger

 

 

The suction pads are designed to lift various items. Only workpieces with a flat, air-
tight surface may be turned with this device. 
To generate vacuum, all suction pads must be in contact with and attached to the 
load (exception: devices with switchable suction pads). 
Individual suction pads can be activated or deactivated with the aid of valves  
on lifting devices with the special feature. 
Deactivating suction pads reduces the load carrying capacity of the device. 
Deactivate suction pads which do not attach themselves to the load, since no 
vacuum can be generated if this is not done. 
Activate or deactivate the suction pads only when no load is attached.  
Attempting to activate or deactivate the suction pads with a load attached will cause 
the vacuum to break down and the load will be dropped. 

 

 

Installation 

4.1  Initiation 

The device must be installed and maintained by qualified personnel, mechanics 
and electricians. Any work on the electrical equipment may be carried out only by a 
qualified electrician. 

The vacuum turning bench 

must

 be securely anchored at its installation location. 

Securing holes are provided in the stands for this purpose. 

Connect the compressed-air supply for the solenoid valve 
(filtered (max. 40 

m) compressed air, with or without oil). 

 

Check the Rotation  
Direction  
(Three-phase Motor) 

 
 
 

Caution

 

 

Switch the pump on. 

 

Watch the fan blade of the motor. It must turn in the direction of the arrow on 

the motor housing. 

 

The unit is designed for use with a three-phase supply with clockwise field. If 

the fan turns in the wrong direction, switch the unit off immediately and swap two 
phase connections.  

 

Check again. 

This may be done only by a trained electrician. 
Damage to the device resulting from rotation in the wrong direction is not covered 
by the warranty. 

 

4.2  Adjusting the 

Suction Pads 

The suction pads are adjustable. To alter the adjustments, unscrew the star-grip 
handles on the glide shoes by one turn. Adjust the suction pads to the desired 
position and retighten the star-grip handle. 

 

4.3  Activating and 

Deactivating 
Suction Pads 
(optional) 

 

Danger

 

Individual suction pads can be activated or deactivated with the aid of valves on 
lifting devices with the appropriate feature. These valves are located either on the 
suction pads or on the vacuum distributor. 

Deactivating suction pads reduces the load carrying capacity of the device. 
Deactivate suction pads which are not in contact with the load. Otherwise, no 
vacuum can be generated. 
Active or deactivate the suction pads only when no load is attached. Attempting to 
activate or deactivate suction pads when a load is attached will cause the vacuum 
to break down and the load will be dropped. 

 

 

Then check the vacuum connections (hoses). 

Содержание VWT-180-4

Страница 1: ...H VWT 180 4 BA 30 30 01 00238 J Schmalz GmbH Aacher Stra e 29 D 72293 Glatten Tel 49 7443 2403 0 Fax 49 7443 2403 259 http www schmalz de e mail schmalz schmalz de Status 03 2013 Index 00 Page 1 16 Pl...

Страница 2: ...e Operator 1 10 Equipment for Personal Protection 1 11 Behaviour in Emergencies 1 12 Checking the Safety Devices 2 Technical Data 3 Description 3 1 Components of the Vacuum Turning Bench 3 2 Controls...

Страница 3: ...permissible load is specified for a vacuum of 0 6 bar and with all suction pads in contact with the workpiece kg Vacuum pump EVE Dead Weight kg Special Features The unit is equipped with the following...

Страница 4: ...ly trained that they have read and understood the operating instructions that the operating instructions are available to them at all times The responsibilities for the tasks carried out with the devi...

Страница 5: ...can constantly observe the vacuum gauge 1 9 Instructions for the Operator As an operator of the vacuum turning bench you must be trained before you start to use the device You must have read and under...

Страница 6: ...leak The reading on the vacuum gauge decreases When the vacuum drops below 0 6 bar the horn of the warning device must sound Checking the Vacuum Hoses and Hose Clamps Check all vacuum hoses and clamp...

Страница 7: ...schmalz de BA 30 30 01 00238 Status 03 2013 Index 00 Page 7 16 3 Description 3 1 Components of the Vacuum Turning Bench Parts with safety functions appear in bold type Pos Description 1 Control panel...

Страница 8: ...ed 6 Switch Manual Foot switch option Activates the optional foot switch for Vacuum On Off and Turn right left If the foot switch is active the controls on the control panel are disabled in order to p...

Страница 9: ...holes are provided in the stands for this purpose Connect the compressed air supply for the solenoid valve filtered max 40 m compressed air with or without oil Check the Rotation Direction Three phas...

Страница 10: ...danger zone below 0 6 bar lower the load immediately If the electronic warning device sounds vacuum below 0 6 bar lower the load immediately Place workpieces only on clear level surfaces since they m...

Страница 11: ...reached you can turn the load Never attempt to lift the load with a lower vacuum since it will be dropped When lifting ensure that only one piece of the items to be lifted is actually lifted Before l...

Страница 12: ...the workpiece air is drawn in Position the device with suction pads completely on the workpiece Filter is dirty Clean replace filter cartridge Filter cover open Screw down the cover Hose defective co...

Страница 13: ...g device actuated at correct pressure vacuum value X X Inspect and maintain the slide and filter of the pump as described in the operating instructions See operating instructions for pump Clean the va...

Страница 14: ...Geared motor See the enclosed Operating Instructions 7 7 Leak Test Danger Check the device for leaks once per month Place an object with an airtight smooth surface such as a sheet of metal on the suc...

Страница 15: ...ating plate is permanently attached to the device Its position is shown in the Spare parts list The rating plate carries the following information Type Device Number Order Number Year of construction...

Страница 16: ...e of non original spare parts and accessories Wear and consumable parts are not covered by the guarantee The most important spare and consumable parts are shown in the following list Abbreviations Spa...

Отзывы: