Schmalz VWT-180-4 Скачать руководство пользователя страница 5

Operating Manual

 

V

ACUUM 

T

URNING BENCH

 

VWT-180-4

 

Chapter 1 

Safety

 

J. Schmalz GmbH 
Aacher Straße  29 
D  - 72293 Glatten 
Tel  +49 +7443 / 2403 - 0 
Fax +49 +7443 / 2403 - 259 
http://www.schmalz.de 
e-mail: [email protected] 

 

 

BA 30.30.01.00238 

Status 03.2013 / Index 00 

Page 5 / 16 

1.6  Emissions 

The equivalent continuous sound pressure level of the device is  
less than 70 dB(A). 

 

1.7  Special Hazards 

Since the load is held by a vacuum, it will fall off as soon as this vacuum is lost.  
This can happen if the power suddenly fails. In such cases, an integrated vacuum 
reservoir maintains the vacuum for a short period (depending on the quality of the 
seal between the suction pads and surface of the workpiece). 

If the power fails, immediately leave the dangerous area near the load. 

The device generates a very strong suction which can draw in hair and clothing. Do 
not look into the suction opening when the device is switched on. Parts of body can 
be sucked in. 

 

1.8  Workplaces 

The workplace of the operator is in front of the control board. Stand so that you can 
constantly observe the vacuum gauge. 

 

1.9  Instructions for 

the Operator 

As an operator of the vacuum turning bench, you must be trained before you start 
to use the device. You must have read and understood the operating instructions 
and especially the chapter "Safety". 

Ensure that only authorised persons use the device. You are responsible for others 
in the operating range of the equipment. 

Local safety requirements are fully applicable. The safety instructions in this 
document complement these local regulations and do not supersede them. 

 

1.10 

Equipment 

for Personal 
Protection 

When operating the device always wear: 

 

safety shoes (with steel toecaps), 

 

tough gloves. 

 

1.11 

Behaviour 

in Emergencies 

An emergency situation exists when 

 

power suddenly fails (device switches off), 

 

the vacuum pressure drops below -0.6 bar to the red section on the scale of the 
vacuum gauge. 

 
Immediately leave the dangerous area near the load, since it will be dropped from 
the device. 

 

1.12 

Checking 

the Safety 
Devices 

The vacuum turning bench is equipped with following safety devices: 

 

vacuum gauge with red danger zone 

 

alarm signal 

Check these devices at the beginning of each shift (when operating in shifts) or 
once a week (when operating continually). 

 

Содержание VWT-180-4

Страница 1: ...H VWT 180 4 BA 30 30 01 00238 J Schmalz GmbH Aacher Stra e 29 D 72293 Glatten Tel 49 7443 2403 0 Fax 49 7443 2403 259 http www schmalz de e mail schmalz schmalz de Status 03 2013 Index 00 Page 1 16 Pl...

Страница 2: ...e Operator 1 10 Equipment for Personal Protection 1 11 Behaviour in Emergencies 1 12 Checking the Safety Devices 2 Technical Data 3 Description 3 1 Components of the Vacuum Turning Bench 3 2 Controls...

Страница 3: ...permissible load is specified for a vacuum of 0 6 bar and with all suction pads in contact with the workpiece kg Vacuum pump EVE Dead Weight kg Special Features The unit is equipped with the following...

Страница 4: ...ly trained that they have read and understood the operating instructions that the operating instructions are available to them at all times The responsibilities for the tasks carried out with the devi...

Страница 5: ...can constantly observe the vacuum gauge 1 9 Instructions for the Operator As an operator of the vacuum turning bench you must be trained before you start to use the device You must have read and under...

Страница 6: ...leak The reading on the vacuum gauge decreases When the vacuum drops below 0 6 bar the horn of the warning device must sound Checking the Vacuum Hoses and Hose Clamps Check all vacuum hoses and clamp...

Страница 7: ...schmalz de BA 30 30 01 00238 Status 03 2013 Index 00 Page 7 16 3 Description 3 1 Components of the Vacuum Turning Bench Parts with safety functions appear in bold type Pos Description 1 Control panel...

Страница 8: ...ed 6 Switch Manual Foot switch option Activates the optional foot switch for Vacuum On Off and Turn right left If the foot switch is active the controls on the control panel are disabled in order to p...

Страница 9: ...holes are provided in the stands for this purpose Connect the compressed air supply for the solenoid valve filtered max 40 m compressed air with or without oil Check the Rotation Direction Three phas...

Страница 10: ...danger zone below 0 6 bar lower the load immediately If the electronic warning device sounds vacuum below 0 6 bar lower the load immediately Place workpieces only on clear level surfaces since they m...

Страница 11: ...reached you can turn the load Never attempt to lift the load with a lower vacuum since it will be dropped When lifting ensure that only one piece of the items to be lifted is actually lifted Before l...

Страница 12: ...the workpiece air is drawn in Position the device with suction pads completely on the workpiece Filter is dirty Clean replace filter cartridge Filter cover open Screw down the cover Hose defective co...

Страница 13: ...g device actuated at correct pressure vacuum value X X Inspect and maintain the slide and filter of the pump as described in the operating instructions See operating instructions for pump Clean the va...

Страница 14: ...Geared motor See the enclosed Operating Instructions 7 7 Leak Test Danger Check the device for leaks once per month Place an object with an airtight smooth surface such as a sheet of metal on the suc...

Страница 15: ...ating plate is permanently attached to the device Its position is shown in the Spare parts list The rating plate carries the following information Type Device Number Order Number Year of construction...

Страница 16: ...e of non original spare parts and accessories Wear and consumable parts are not covered by the guarantee The most important spare and consumable parts are shown in the following list Abbreviations Spa...

Отзывы: