General Description of Functions
30 / 72
EN-US · 30.30.01.02084 · 02 · 12/20
If you activate ECO mode using IO-Link, the display will immediately enter energy-saving
mode.
7.17 Write Protection
A PIN can be used to prevent the parameters from being changed via the user menu.
The current settings are still displayed. The PIN is set to
000
on delivery. meaning access to the parame-
ters is not locked. A valid PIN between
001
and
999
must be entered to activate write protection. If
write protection is activated with a customer-specific PIN, the desired parameters can be changed within
one minute after the correct code is entered. If no changes are made within one minute, write protection
is automatically reactivated. The PIN
000
must be set again to permanently deactivate the lock.
Full access to the ejector is still possible via IO-Link even if a PIN is enabled. The current PIN can also be
read out and changed/deleted (PIN =
000
) via IO-Link.
You enter the PIN using the
PIN
parameter in the configuration menu or via IO-Link.
In IO-Link mode, the “Device access locks” default parameter is available to prevent changes to parameter
values using the user menu or IO-Link. You can also prevent the use of the Data storage mechanism de-
scribed in IO-Link Standard V1.1.
Bit
Meaning
0
Parameter write access locked
(Parameters cannot be changed via IO-Link)
1
Data storage locked
(Data storage mechanism is not triggered)
2
Local parametrization locked
(Parameters cannot be changed via the user menu)
Coding for the device access locks
A menu lock using the Device access locks parameter has a higher priority than the menu PIN. In other
words, this lock cannot be bypassed by entering a PIN and remains in SIO mode.
It can only be canceled via IO-Link, not via the ejector or the vacuum switch itself.
7.18 Resetting to Factory Settings
This function restores the ejector configuration of the initial setup and the settings of the active produc-
tion setup profile to the factory settings.
WARNING
By activating/deactivating the product, output signals lead to an action in the pro-
duction process!
Personal injury
4
Avoid possible danger zone.
4
Remain vigilant.
The function is executed using the
rE5
menu item in the configuration menu or via IO-Link:
1. Press the
button for more than 3 seconds.
ð
When the menu is locked, enter the valid PIN.
2. Use the
or
button to select the
rE5
menu item.
3. Confirm using the
button.
ð
YE5
appears on the display.