General handling / operation
Operating Manual
| Edition 1.00 (08-2020) | ACO 08
29 | 52
Signal inverse
Mode of the PLC/stop signal
Normal/inverse
Filter
Noise filter
on/off
Calibration factor
Calibration factor for comparison of calibration
values
0.01 - 100
Trigger category
Option
Description
Value
Trigger mode
Mode of the start encoder:
■
External: External start encoder
■
Internal 1: Start encoder through
generated sensor force on channel 1
■
Internal 2: Start encoder through
generated sensor force on channel 2
Ext/Int1/Int2
Trigger level
Force value for internal start encoder (if active)
1-99 %
Trigger offset
Time shift of the starting time to the start
encoder
-2000-2000
measuring
points
Crimp category
Option
Description
Value
Reference amount
Number of crimps to form the reference
curve
1 - 100
Sample Factor
Enlarging the measuring window for longer
crimping processes by skipping n-1
measurements
1-20
Aktive channels
Determines which channels are activated.
Ch1/ch2/ch1+
2
Shift curve peak
Shifts the crimping curves to the X axis (time)
and superimposes them at the maximum
value to compensate for irregular times.
on/off
Always acknowledge
error
On:
Requires acknowledgment in case of
error
Off:
No acknowledgment, machine
continues running
Secure: Acknowledgment by password entry
on/off/secure
Auto reference check
Evaluates the deviation of curves automatically
in reference mode. Each reference must be
confirmed manually if disabled.
on/off
Содержание ACO 08
Страница 1: ...ACO 08 Crimp Force Monitor Operating manual Edition 1 00 08 2020...
Страница 46: ...Exploded drawings 46 52 Operating Manual Edition 1 00 08 2020 ACO 08 12 EXPLODED DRAWINGS...
Страница 47: ...Block diagram Operating Manual Edition 1 00 08 2020 ACO 08 47 52 13 BLOCK DIAGRAM...
Страница 48: ...PLC Interface 48 52 Operating Manual Edition 1 00 08 2020 ACO 08 14 PLC INTERFACE...
Страница 49: ...PLC Interface Operating Manual Edition 1 00 08 2020 ACO 08 49 52...
Страница 50: ...Notes 50 52 Operating Manual Edition 1 00 08 2020 ACO 08 15 NOTES...
Страница 52: ...Index 52 52 Operating Manual Edition 1 00 08 2020 ACO 08...