Product specifications
16 | 52
Operating Manual | Edition 1.00 (08-2020) | ACO 08
Description
Value
Swivel in the unit
Digital IO
Trigger
external, internal
Feed connection
Operating voltage
12 – 24
VDC
Power consumption (max.)
10
W
4.3
SETUP LOCATION
Set up on hard nonfragile surface or mount to the crimping machine.
4.4
RATING PLATE
To ensure our efficient support, we request the customer to always submit the exact content of the
rating plate when contacting us with requests.
The rating plate is located on the side wall and contains the following specifications.
1 Product
4 Permissible operating voltages
2 Serial number
5 Internal fuses
3 Year of manufacture
6 Manufacturer
1
2
6
3
4
5
Содержание ACO 08
Страница 1: ...ACO 08 Crimp Force Monitor Operating manual Edition 1 00 08 2020...
Страница 46: ...Exploded drawings 46 52 Operating Manual Edition 1 00 08 2020 ACO 08 12 EXPLODED DRAWINGS...
Страница 47: ...Block diagram Operating Manual Edition 1 00 08 2020 ACO 08 47 52 13 BLOCK DIAGRAM...
Страница 48: ...PLC Interface 48 52 Operating Manual Edition 1 00 08 2020 ACO 08 14 PLC INTERFACE...
Страница 49: ...PLC Interface Operating Manual Edition 1 00 08 2020 ACO 08 49 52...
Страница 50: ...Notes 50 52 Operating Manual Edition 1 00 08 2020 ACO 08 15 NOTES...
Страница 52: ...Index 52 52 Operating Manual Edition 1 00 08 2020 ACO 08...