27
/
33
6. Module mounting and module clamping
The module clamping is carried out according to the project planning (vertical,
horizontal or combined module arrangement). The distance between modules can
deviate from the standard value.
Standard value:
•
clamped side
23 mm
•
side without clamping
5 - 10 mm
(according to the specifi cations in the technical drawing; specifi cations by the
module manufacturer are considered)
23 mm
5 - 10 mm
Clearance (= distance between module and module clamp) of
•
min. 0.5 mm
•
max. 2 mm
must be observed (module abuts on the spacer notches).
0.5 - 2 mm
0.5 - 2 mm
Fig. 6.-1 (distance between modules)
Fig. 6.-2 (clearance)
Solar modules are third party components that are not included in the scope of delivery of the
FS Uno substructure. Schletter GmbH thus points out that the safety notices and
mounting instructions of the module manufacturer are to be observed. And please also note the notices
given in these Mounting Instructions when mounting the photovoltaic modules!
The following points must be taken into consideration at any event:
•
Photovoltaic modules are electric devices. They must be treated carefully!
•
Impacts, kicks, shocks or vibrations must be avoided.
•
It is not allowed to put loads on the modules (trespassing, storing of items, etc.).
•
Scratches or dirts on the module surface must be avoided.
•
It is not allowed to pull or tear at the module cables. Do not heavily bend the module cables.
Observe the clamping points specifi ed by the module manufacturer!
Please note the data sheet of the photovoltaic module provided by the manufacturer to verify the
clamping points.
Schletter Solar GmbH – Alustraße 1 – 83527 Kirchdorf
Mounting instruction
FS UNO
with SRF Foundation Posts
| 2016.09 V.00
4