E X P L O S I O N P R O O F

2 / 4

ExCos-D...

Technical data 

ExCos-D...

Accessories

Explosion proof 

ExCos-D...

Power supply 

24 VAC/DC ± 20%  (19,2 ... 28,8 VAC/DC)  50...60 Hz 

Current, power consumption

 

  150 mA, ~ 4 W, internal fuse 500 mAT, without bracket, not removable

Galvanic isolation

 

supply – analogue output 1,5 kV (Ex 60 V)

Electrical connection 

terminals 0,14…2,5 mm² at integrated Ex-e junction box

Cable entry 

M16 × 1,5 mm Ex-e approved, cable diameter ~ Ø 5...10 mm, (

...-CT 

in nickel-plated)

 

Protection class 

Class I (grounded)

Display 

2 × 16 digits, dot-matrix with backlight, display for configuration, user guidance, parameter and actual value indication

Control elements

 

3 buttons for configuration

Housing protection 

IP66 in acc. to IEC 60529

Housing material 

aluminium casting, coated (

...-CT

 = version in marine painting, seawater-resistant)

Dimensions/weight

 

L × W × H = 180 × 107 × 66 mm / ca. 950 g

Ambient temperature/-humidity  

–20…+50 °C / 0…95 % rH, non condensed

Storage temperature

 

–40…+70°C

Sensor connection

 

Only for ExPro-C... sensors!

 via plug-and-socket connection at front or back side of the transducer, to appropriate the use for room or 

 

duct mounting. 

Attention:

 only one ExPro-C... probe can be connected to one transducer!

ExPro-C... sensors

 

please have a look on the separate data sheet for ExPro-C... sensors 

Measuring range

 

measuring ranges are scalable within the maximum measuring range  

Maintenance

 

maintenance free, nevertheless maintenance must be complied with regional standards, rules and regulations 

Response time of sensor 

T90 ~ 1 s

Accuracy temperature

  

± 0,2 % of end value + accuracy of ExPro-C... sensor ± 0,3 °C at 25 °C ± 0,025 °C/°C

Accuracy humidity

 

± 0,2 % of end value + accuracy of ExPro-C... sensor 10…90 % rH ± 2% and < 10 % rH and > 90 % rH ± 4% + 1% hysteresis

Non linearity and hysteresis 

± 0,1 % of end value

Start delay 

5 s

Stability

 

long term stability < 0,2 %/year, temperature influence < 0,02 %/K, supply voltage influence < 0,01 %

Output 

 

voltage U (V) or current I (mA) selecable via menu on site (at combi sensors not separately adjustable)

Output protection

 

against short circuit and external voltage up to 24 V, protected against polarity reversal

 

Voltage output U

 

from 0...10 VDC adjustable, invertible, burden > 1 kΩ, influence < 0,05% / 100 Ω

Current output I

 

from 0...20 mA adjustable, invertible, burden < 500 Ω, influence < 0,1%  / 100 Ω

open circuit voltage < 24 V

Output at alarm mode 

 

increasing or decreasing output signal, selectable on site, down to 0 VDC/0 mA or up to 10 VDC/20 mA

Wiring diagram (SB)

 

SB 2.0

 

Delivery (changeable on site)

 

output 4…20 mA, output with decreasing alarm situation to 0 V/0 mA

Included in delivery

 

ExCos-D... with 3 screws 4,2 × 13 mm self-tapping

Installation area transducer

 

  in Ex-area zone 1, 2, 21, 22

Additional information for ExCos-D-A:
Analogue output

 

  (0)4…20 mA

Ex-i 

 

  Intrinsically Safe (IS)

Burden

 

  max. 400 Ω

Accuracy  

± 0,5 % 

 

Plug

 

  cable diameter Ø 6...8 mm 

 

Delivery version ...-D-A

 

  incl. 2 × plug

PTB-testet 

PTB 07 ATEX 2061

acc. to ATEX directive 

94/9/EC (ATEX)

Approval for gas 

II2(1)G Ex e ma [ia] IIC T6  

for zone 1, 2

Approval for dust 

II2(1)D Ex tD A21 [iaD] IP66 T80°C   for zone 21, 22

Identification 

CE No. 0158 

EMC 

2004/108/EC EMC directive 

Electrical safety 

2006/95/EC low voltage directive 

Protection type 

IP66 in acc. to EN 60529

Potential compensation 

external PA-terminal, 4 mm²

EXC-RIA-16

   LCD indicator (IS), installation in Ex-areas zones 1, 2, 21, 22, 

 

connectable directly to ...Cos-... transducer

MKR

  

Mounting bracket for round ducts up to Ø 600 mm

MFK

  

Mounting flansh for probe positioning

Содержание ExPro-CTF Series

Страница 1: ...xCos D transducer generation from together with direct coupled ExPro C sensors are a revolution for measuring temperature and or humidity in HVAC systems in chemical pharmaceutical industrial and Offshore Onshore plants for use in hazardous areas zone 1 2 gas and zone 21 22 dust Highest protection class ATEX and IP66 protection small dimension universal functions and technical data guarantee safe ...

Страница 2: ...end value accuracy of ExPro C sensor 0 3 C at 25 C 0 025 C C Accuracy humidity 0 2 of end value accuracy of ExPro C sensor 10 90 rH 2 and 10 rH and 90 rH 4 1 hysteresis Non linearity and hysteresis 0 1 of end value Start delay 5 s Stability long term stability 0 2 year temperature influence 0 02 K supply voltage influence 0 01 Output voltage U V or current I mA selecable via menu on site at combi ...

Страница 3: ...ly one sensor to one transducer In acc with the sensor type you need to set parameter for one or two measuring ranges Wiring diagram ExCos D Values intrinsically safe IS for ExPro C sensors Password input Parameter Wiring Ex i output optional at ExCos D A transducer Important information for installation and operation A Installation commissioning maintenance The cable has to be drawn through the c...

Страница 4: ...reasing decreasing Menu 11 unit sensor 2 select physical unit Menu 12 Menu 13 Menu 14 Menu 15 Menu 16 output Ex i 1 option only at ExCos D A adjust 4 20 mA or 0 20 mA IS output signal Menu 17 Menu 18 Menu 19 display function select display on off illuminated or backlight off Menu 20 password select password protection Menu 21 save and exit select save data factory setting discard or back to menu M...

Отзывы: