29
Typical Installations
Open up the exterior wall.
Insert Ignis-Protect so that it fits
perfectly. The side laminated with
foil should be facing inwards!
If necessary correct the opening.
Replace the thermal insulation right
around the assembly opening in the
studwork.
IMPORTANT: follow the
safe working notes on page 29.
View of the finished vapour barrier
sealed tightly all round.
Check width of the opening: 565mm
NOTE: Ignis-Protect must not be
shortened on site!
With Ignis-Protect in place, cut away
the vapour barrier flush to the edges.
Check height of the opening (see
image 2.)
NOTE: Ignis-Protect must
not be shortened on site!
Secure the junctions with the vapour
barrier by applying appropriate sealing
tape to the foil lamination.
No gaps should be
left in the studwork
or the surrounding
thermal insulation!
TIP:
9
8
11
14
13
10
12
15
Ignis-Protect