background image

 

19 

4. Maintenance  
4.2 Verifications and periodic maintenance  

 

The following periodic procedures are to be followed to maintain trouble free operation: 
 

OPERATION 

EVERY 

PROCEDURE 

 
 
 
Strainer check and 
cleaning  

 
 
 
Every 5 days 

Check and clean  

 

 
 
 
 
5 micron cartridge 
replacement 
 

Every  15-20  days  in 
average  conditions  (4 
hours/day usage).  
Anyway replace it when 
the message  

CHANGE  PUMP FILTERS 

appears. 

Unscrew anticlockwise the filter 
holder.  

 

 

 
 
 
Active carbon filter 
replacement  
 

 
 
Every 6 months 
 
Close  the  grey  valve 
before open the filter 
 

 

 

 

Purge periodically 
the air from the 
system, opening at 
45° for a couple of 
minutes the 
depressurization 
valve 

 

 
 
 

Every 15 days 

 

 

Check the pressure on the manometer located on 
the front panel. 
The  working  pressure  depends  on  many  factors 
such  as  water  temperature,  salinity  level  of 
seawater, 

battery 

voltage, 

cleanliness 

of 

membranes and type of installation. 
The  pressure,  under  mid  range  working 
conditions  is  approx.  6,5-7    BAR.  There  is  a 
small  pressure  loss  ,  in  the  range  of  0,2  Bars, 
during the cycle. 

 

 

 

 

 

Содержание MODULAR 30 digital

Страница 1: ...aterial required 2 2 Components mounting 2 3 Water intake 2 4 Hydraulic connections 2 5 Electric connections 3 Operating procedures 3 1 Remote panel commands 3 2 First start up procedure 3 3 Normal op...

Страница 2: ...Y RECOVERY SYSTEM which amplifies the pressure of common low pressure pumps and recoups all the hydraulic energy back from the membrane This saves on the use of power allowing the Modular 60 to be run...

Страница 3: ...weight 7 Kg Connections Seawater intake holder for hose int diam 16 mm Salt water outlet holder for hose int diam 16 mm Filter 5 micron polyestere pleated type Power supply 12 Vdc 20 version 30M12 24...

Страница 4: ...et pressure The movement required is very small 1 4 turn 1 BAR This action will not be required in normal circumstances as the unit has been pre calibrated at the factory Before changing the settings...

Страница 5: ...roduced fresh water coming out of the unit This is only indicative as the accuracy of the flowmeter is 20 Depressurization valve Is used only during the air bleeding phase at the first plant start up...

Страница 6: ...protected from water It is connected to the remote panel and controls the functions of the watermaker automatically The microswitches P1and EV allow the direct command of the pump the electrovalve res...

Страница 7: ...ht when the filter housing is full of water It may be necessary to create a suitable wooden or fiberglass structure for the unit if an existing one not available The base of the pump is equipped with...

Страница 8: ...must be secured with double hose clamps It is not advisable to Tee into the engine cooling water intake as it may impair the cooling of the engine An easily inspected mesh type filter will be require...

Страница 9: ...einforced hose An inadequate hose could burst jeopardizing seriously the safety of the boat The hydraulic connections are Low pressure max 3 bar connections sea water inlet net filter backflow valve i...

Страница 10: ...rantee a water head PRODUCTION FRESH WATER CONNECTION The connection has to be made using the small hose supplied with the equipment The connection has to be made between the polyethylene pipe that co...

Страница 11: ...able below Voltage Automatic Cable lenght switch up to 3 mts 3 7 mt 7 10 mt Volt Ampere mm2 AVG mm2 AVG mm2 AVG 12 16 4 11 10 7 16 5 24 10 2 5 13 4 11 4 11 Electric cables and switches selection table...

Страница 12: ...12 Wiring connection diagram Signal pressure switch Electrovalve...

Страница 13: ...uddenly It awaits for the correct positioning of the internal valve 2 3 seconds and then stops automatically If the automatic washing is activated washing light on the system once pushed STOP will per...

Страница 14: ...cartridge replacement or a general service The procedure allows to purge completely the air from the system and from the seawater and the washing fresh water hoses The depressurization valve must be...

Страница 15: ...rge out the air from the system It can be used as well after a filter replacement or after other maintenance operations Preliminary checks Verify that all components are connected correctly Verify tha...

Страница 16: ...row the specific timer menu the system will hold as well the previous setting Push the button START for more than 3 seconds The display will show the decreasing production time The system will stop af...

Страница 17: ...n to jam again resulting in a typical start stop noise After approx 20 sec the computer recognize the problem and turn off the pumps and the message WARNING SYSTEM BLOCKED is displayed This event besi...

Страница 18: ...efully following the indications on the pack Wear a protection mask in order to avoid inhaling product dusts The water temperature doesn t have to be lower than 25 C preferably 3 Close the grey valve...

Страница 19: ...e the filter holder Active carbon filter replacement Every 6 months Close the grey valve before open the filter Purge periodically the air from the system opening at 45 for a couple of minutes the dep...

Страница 20: ...5 Bar Cold sea water Filter clogged Dirty membranes Normal operation Clean filter Perform cleaning cycle Leaking in the plant Loose connectors ERS loss Tighten connectors Contact a service point Prob...

Страница 21: ...S Unless the correct cleaning procedures are carried out in accordance with this manual there may be bacteria present in the produced water Therefore avoid drinking the water produced by the plant if...

Страница 22: ...Service Point or our factory will be on customer account The under guarantee delivered parts transport will be at customer s own risk In case of repairs under guarantee directly performed by our techn...

Отзывы: